Молниеотвод
Главная / Продукты / Молниеотвод / ZnO / Metal-oxide arrester

Молниеотвод

ZnO / металлооксидный предохранитель

ZnO / Metal-oxide arrester protects distribution line,transformer,cable connector and electric equipment from being damaged by lightning impulse voltage and operated over-voltage.
Обзор

Metal oxide surge arrester

Metal Oxide Surge Arrester Range for Distribution Protection

FUERTE’s supplier-published ZnO arrester table covers 3–36 kV rated-voltage models with 5 kA and 10 kA nominal discharge-current options and 2.55–29 kV MCOV values.

Номинальное напряжение
3–36 kV
Nominal discharge current
5 / 10 kA
MCOV
2.55–29 kV
Published standard
IEC60099-4 / IEEE C62.11

The supplier page lists IEC60099-4 and IEEE C62.11 as the technical standards; confirm the required edition and project acceptance documents before ordering.

Запросите обзор конфигурацииBrowse lightning arresters

Published technical data

Polymer Surge Arrester Technical Range

Use the published family table to shortlist rated voltage, nominal discharge current, MCOV and residual-voltage levels before checking the project insulation-coordination study.

Model Rated Voltage Nominal Discharge Current MCOV 1/4 μs Lightning Current Impulse 8/20 μs Lightning Current Impulse 30/60 μs Swilching Current Impulse 2ms Reclangular Current Impulse Withstand 4/10 μs High Current Impulse Withstand
kV(rms) kA kV(rms) kV(Cresl) kV (Crest) kV (Crest) A kA (Crest)
YH5W-3 3 5 2.55 11.3 9 8.9 150 65
YHIOW-3 3 10 2.55 11.3 9 8.9 250 100
YH5W-6 6 5 5.1 22.6 18 16.8 150 65
YH10W-6 6 10 5.1 22.6 18 16.8 250 100
YH5W-9 9 5 7.65 33.7 27 23.8 150 65
YH10W-9 9 10 7.65 33.7 27 23.8 250 100
YH5W-10 10 5 8.4 36 30 26.4 150 65
YH10W-10 10 10 8.4 36 30 26.4 250 100
YH5W-11 11 5 9.4 40 33 30 150 65
YH10W-11 11 10 9.4 40 33 30 250 100
YH5W-12 12 5 10.2 42.2 36 31.7 150 65
YH10W-12 12 10 10.2 42.2 36 31.7 250 100
YH5W-15 15 5 12.7 51 45 38.5 150 65
YH10W-15 15 10 12.7 51 45 38.5 250 100
YH5W-18 18 5 15.3 61.5 54 46.2 150 65
YH10W-18 18 10 15.3 61.5 54 46.2 250 100
YH5W-21 21 5 17 71.8 63 54.2 150 65
YH10W-21 21 10 17 71.8 63 54.2 250 100
YH5W-24 24 5 19.5 82 72 62 150 65
YH10W-24 24 10 19.5 82 72 62 250 100
YH5W-27 27 5 22 92 81 69.8 150 65
YH10W-27 27 10 22 92 81 69.8 250 100
YH5W-30 30 5 24.4 102 90 79 150 65
YH10W-30 30 10 24.4 102 90 79 250 100
YH5W-33 33 5 27.5 112 99 86.7 150 65
YH10W-33 33 10 27.5 112 99 86.7 250 100
YH5W-36 36 5 29 123 108 92.4 150 65
YH10W-36 36 10 29 123 108 92.4 250 100

Confirm the selected rating against the system voltage, earthing arrangement, insulation coordination, installation altitude and pollution conditions.

Список контрольных критериев отбора

Prepare the Surge Arrester RFQ

  1. State the system and arrester voltage. Include the nominal system voltage, arrester rated voltage and MCOV.
  2. Confirm discharge duty. Specify nominal discharge current, required residual-voltage limits and the project duty cycle.
  3. Define installation conditions. Include altitude, pollution level, maximum ambient temperature and mounting position.
  4. Select hardware and accessories. Confirm brackets, line clamps, earth leads, disconnectors, bird guards, counters or monitors.
  5. List document requirements. State the applicable standard edition, drawings, test evidence and acceptance documents required by the project.

Configuration and supply boundary

Review the ZnO Arrester Configuration

The source describes Grade 304 stainless steel terminal hardware and optional NEMA A or B mounting brackets, earth leads, line clamps, bird guards, disconnectors, discharge counters and monitors.

Electrical coordination

Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.

Mounting hardware

State bracket pattern, terminal connection, line clamp and earth-lead requirements in the inquiry.

Failure indication

Confirm whether the supply should include a disconnector, insulating base, counter or monitor.

Commercial boundary

Quantity, packing, delivery schedule, test documents and destination requirements depend on quotation.

Масштаб компании

Fuerte в общих чертах

FUERTE называет 1985 год годом основания, 220+ сотрудников и площадь здания 36 000 м². Эти данные, опубликованные поставщиками, дают представление о масштабах производства и поддержки проектов.

  • Операции на фабрике
  • Тестирование и инспекция
  • Поддержка экспорта

1985

Основанная в

Supplier-published company history

220+

Сотрудники

Published workforce scale

36,000 m²

Застроенная территория

Published manufacturing footprint

OEM

Поддержка ODM

Subject to technical review

О компании FUERTE

Возможность разработки и производства под заказ

Custom Support for Arrester Projects

FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.

  • Electrical configurationReview rated voltage, MCOV, discharge current, residual voltage and service conditions.

  • Hardware selectionConfirm brackets, terminals, disconnectors, bird guards, counters and monitors.

  • Project documentationState drawing, marking, packing and acceptance-document requirements before quotation.

Выставочный зал электротоваров FUERTE

Часто задаваемые вопросы

ZnO family Surge Arrester FAQ

What rated-voltage range is published?

The family table lists rated-voltage models from 3 kV through 36 kV.

Which nominal discharge currents are listed?

The published table provides 5 kA and 10 kA model options.

Which standards are stated?

The source lists IEC60099-4 and IEEE C62.11. Confirm the required edition and acceptance scope in the RFQ.

Which accessories can be requested?

The supplier page lists mounting brackets, an earth lead, a line clamp, a bird guard, a disconnector, a discharge counter and a monitor as selectable items.

Обзор конфигурации

Send the ZnO family Requirements

Provide system voltage, arrester rated voltage, MCOV, nominal discharge current, residual-voltage limits, mounting and accessory requirements, quantity, destination market and required documents.