Electrical coordination
Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.


Metal oxide surge arrester
FUERTE’s supplier-published ZnO arrester table covers 3–36 kV rated-voltage models with 5 kA and 10 kA nominal discharge-current options and 2.55–29 kV MCOV values.
The supplier page lists IEC60099-4 and IEEE C62.11 as the technical standards; confirm the required edition and project acceptance documents before ordering.
Published technical data
Use the published family table to shortlist rated voltage, nominal discharge current, MCOV and residual-voltage levels before checking the project insulation-coordination study.
| نموذج | Rated Voltage | Nominal Discharge Current | MCOV | 1/4 μs Lightning Current Impulse | 8/20 μs Lightning Current Impulse | 30/60 μs Swilching Current Impulse | 2ms Reclangular Current Impulse Withstand | 4/10 μs High Current Impulse Withstand |
| kV(rms) | كا | kV(rms) | kV(Cresl) | kV (Crest) | kV (Crest) | A | kA (Crest) | |
| YH5W-3 | 3 | 5 | 2.55 | 11.3 | 9 | 8.9 | 150 | 65 |
| YHIOW-3 | 3 | 10 | 2.55 | 11.3 | 9 | 8.9 | 250 | 100 |
| YH5W-6 | 6 | 5 | 5.1 | 22.6 | 18 | 16.8 | 150 | 65 |
| YH10W-6 | 6 | 10 | 5.1 | 22.6 | 18 | 16.8 | 250 | 100 |
| YH5W-9 | 9 | 5 | 7.65 | 33.7 | 27 | 23.8 | 150 | 65 |
| YH10W-9 | 9 | 10 | 7.65 | 33.7 | 27 | 23.8 | 250 | 100 |
| YH5W-10 | 10 | 5 | 8.4 | 36 | 30 | 26.4 | 150 | 65 |
| YH10W-10 | 10 | 10 | 8.4 | 36 | 30 | 26.4 | 250 | 100 |
| YH5W-11 | 11 | 5 | 9.4 | 40 | 33 | 30 | 150 | 65 |
| YH10W-11 | 11 | 10 | 9.4 | 40 | 33 | 30 | 250 | 100 |
| YH5W-12 | 12 | 5 | 10.2 | 42.2 | 36 | 31.7 | 150 | 65 |
| YH10W-12 | 12 | 10 | 10.2 | 42.2 | 36 | 31.7 | 250 | 100 |
| YH5W-15 | 15 | 5 | 12.7 | 51 | 45 | 38.5 | 150 | 65 |
| YH10W-15 | 15 | 10 | 12.7 | 51 | 45 | 38.5 | 250 | 100 |
| YH5W-18 | 18 | 5 | 15.3 | 61.5 | 54 | 46.2 | 150 | 65 |
| YH10W-18 | 18 | 10 | 15.3 | 61.5 | 54 | 46.2 | 250 | 100 |
| YH5W-21 | 21 | 5 | 17 | 71.8 | 63 | 54.2 | 150 | 65 |
| YH10W-21 | 21 | 10 | 17 | 71.8 | 63 | 54.2 | 250 | 100 |
| YH5W-24 | 24 | 5 | 19.5 | 82 | 72 | 62 | 150 | 65 |
| YH10W-24 | 24 | 10 | 19.5 | 82 | 72 | 62 | 250 | 100 |
| YH5W-27 | 27 | 5 | 22 | 92 | 81 | 69.8 | 150 | 65 |
| YH10W-27 | 27 | 10 | 22 | 92 | 81 | 69.8 | 250 | 100 |
| YH5W-30 | 30 | 5 | 24.4 | 102 | 90 | 79 | 150 | 65 |
| YH10W-30 | 30 | 10 | 24.4 | 102 | 90 | 79 | 250 | 100 |
| YH5W-33 | 33 | 5 | 27.5 | 112 | 99 | 86.7 | 150 | 65 |
| YH10W-33 | 33 | 10 | 27.5 | 112 | 99 | 86.7 | 250 | 100 |
| YH5W-36 | 36 | 5 | 29 | 123 | 108 | 92.4 | 150 | 65 |
| YH10W-36 | 36 | 10 | 29 | 123 | 108 | 92.4 | 250 | 100 |
Confirm the selected rating against the system voltage, earthing arrangement, insulation coordination, installation altitude and pollution conditions.
قائمة التحقق من الاختيار
الحدود الخاصة بالتكوين والإمداد
The source describes Grade 304 stainless steel terminal hardware and optional NEMA A or B mounting brackets, earth leads, line clamps, bird guards, disconnectors, discharge counters and monitors.
Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.
State bracket pattern, terminal connection, line clamp and earth-lead requirements in the inquiry.
Confirm whether the supply should include a disconnector, insulating base, counter or monitor.
Quantity, packing, delivery schedule, test documents and destination requirements depend on quotation.



حجم الشركة
تُذكر FUERTE عام 1985 باعتباره عام تأسيسها، كما تُذكر وجود أكثر من 220 موظفاً وتخطيط مساحة تبلغ 36,000 متر مربع. وتوفر هذه الأرقام التي نشرها الموردون السياق اللازم لتصنيع المشروع ودعمه.
1985
تاريخ الشركة حسبما نشرته الشركة
220+
قياس القوة العاملة المنشورة
36,000 متر مربع
التواجد المكتبي المعتمد
التصنيع باستخدام التصميم الخاص بالعميل
خاضعاً لمراجعة فنية
قدرة التصنيع حسب الطلب (OEM) وODM
يتضمن نطاق أعمال FUERTE المطبوعة في مجال تصنيع المعدات الأصلية والتصنيع بالتوافق مع العلامة التجارية، تركيب الأجهزة، لوحات الاسم، التغليف، وعلامات الشحن.
Electrical configurationReview rated voltage, MCOV, discharge current, residual voltage and service conditions.
Hardware selectionConfirm brackets, terminals, disconnectors, bird guards, counters and monitors.
وثائق المشروعState drawing, marking, packing and acceptance-document requirements before quotation.

الأسئلة الشائعة
The family table lists rated-voltage models from 3 kV through 36 kV.
The published table provides 5 kA and 10 kA model options.
The source lists IEC60099-4 and IEEE C62.11. Confirm the required edition and acceptance scope in the RFQ.
The supplier page lists mounting brackets, an earth lead, a line clamp, a bird guard, a disconnector, a discharge counter and a monitor as selectable items.
استعراض التكوين
Provide system voltage, arrester rated voltage, MCOV, nominal discharge current, residual-voltage limits, mounting and accessory requirements, quantity, destination market and required documents.
هل ترغب في الحصول على هذا المنتج؟ قم بتعبئة النموذج أدناه وسيقوم فريق المبيعات لدينا بالرد عليك في غضون 24 ساعة.
لا تتردد في ترك رسالة للاستشارة. سنقدم لك المزيد من خيارات الخدمة.