Electrical coordination
Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.
Metal oxide surge arrester
The supplier table identifies Y5(10W)-36 as a 36 kV, 50 Hz, gapless Design B distribution-type surge arrester with 5 / 10 kA nominal discharge-current options and 29 kV maximum continuous operating voltage.
The source lists IEC60099-4:2014. Confirm the required standard edition, arrester class and project acceptance documents before ordering.
Published technical data
Review the published electrical characteristics together with the selectable accessories, material options, package information and service conditions.
| Электрические характеристики | Спецификация | Унита | |
|---|---|---|---|
| Rated voltage of Surge arrreser | 36 | kV | |
| Nominal discharge current | 5 | 10 | kA |
| Rated frequency | 50 | Hz | |
| Maximum continuous operating voltage | 29 | kV | |
| Steep current impulse residual voltage | 123 | kV(Crest) | |
| Lightning Impulse residual voltage | 108 | kV(Crest) | |
| Switching Impulse residual voltage | 92.4 | kV(Crest) | |
| Long duration current impulse
withstand voltage |
150 | 250 | A |
| High current impulses | 65 | 100 | kA (Crest) |
| Rated Short-circuit current | 20 / 12 / 6 / 0.6 ± 0.2 | kA | |
| Class of Surge arrester | Class 1 or Class 2 | ||
| Приложение | Distribution type | ||
| With or without gap | Gapless | ||
| Designation of arrester | Design B | ||
| Запасные части | |||
| NEMA A or B mounting bracket | с/без | ||
| Отключающий элемент | с/без | ||
| Earth lead | с/без | ||
| Bird guard cap | с/без | ||
| Line clamp | с/без | ||
| Upper terminal (incoming line) bolt size | M12 | ||
| Lower termina (outgoing line) bolt size | M10 | ||
| Материал | |||
| Upper terminal | Stainless steel 304 | ||
| Housing | Polymer type | ||
| Color of housing | Dark grey / light grey | ||
| Varistor | High quality zinc oxide varistor | ||
| Size of Varistor | 35mm / 38mm /40mm / 42mm | ||
| Пакет | |||
| Количество/пакет | 3 | ПК/бумага | |
| Условия обслуживания | |||
| Максимальная температура окружающей среды | 40 | ℃ | |
| Уровень загрязнения | Heavy | ||
| Высота | 1000 | Метр | |
| Стандартный | IEC60099-4:2014 | ||
Confirm the selected rating against the system voltage, earthing arrangement, insulation coordination, installation altitude and pollution conditions.
Список контрольных критериев отбора
Configuration and supply boundary
The supplier table lists a polymer housing, Grade 304 stainless steel upper terminal and zinc oxide varistor options sized 35mm / 38mm /40mm / 42mm.
Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.
State bracket pattern, terminal connection, line clamp and earth-lead requirements in the inquiry.
Confirm whether the supply should include a disconnector, insulating base, counter or monitor.
Quantity, packing, delivery schedule, test documents and destination requirements depend on quotation.



Масштаб компании
FUERTE называет 1985 год годом основания, 220+ сотрудников и площадь здания 36 000 м². Эти данные, опубликованные поставщиками, дают представление о масштабах производства и поддержки проектов.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
Возможность разработки и производства под заказ
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview rated voltage, MCOV, discharge current, residual voltage and service conditions.
Hardware selectionConfirm brackets, terminals, disconnectors, bird guards, counters and monitors.
Project documentationState drawing, marking, packing and acceptance-document requirements before quotation.

Часто задаваемые вопросы
The table lists 36 kV rated voltage and 29 kV maximum continuous operating voltage.
The published steep-current, lightning-impulse and switching-impulse residual voltages are 123 kV, 108 kV and 92.4 kV crest respectively.
The source identifies the product as a gapless, Design B, distribution-type arrester.
State the system voltage, MCOV, nominal discharge current, residual-voltage limits, short-circuit requirement, mounting hardware, disconnector, terminal sizes, quantity and destination market.
Обзор конфигурации
Provide system voltage, arrester rated voltage, MCOV, nominal discharge current, residual-voltage limits, mounting and accessory requirements, quantity, destination market and required documents.
Интересует этот товар? Заполните форму ниже, и наш продакт-менеджмент свяжется с вами в течение 24 часов.
Пожалуйста, оставляйте сообщения для консультации. Мы предложим вам больше вариантов обслуживания.