  • The disconnect switch / isolating switch with manual operation mechanism is used for sectionalizing or isolating circuits on outdoor distribution overhead systems up to 38KV.
  • Характеристика:
  • Voltage: 12 / 36kV
  • Current: 400 / 630A
  • Application: Overhead Distribution Line
  • Standard: IEC 62271-102
Обзор

Medium-voltage isolating switch

GW13-15 Isolating Switch for Medium-Voltage Distribution Isolation

GW13-15 Isolating Switch is a medium-voltage isolating switch for outdoor distribution isolation. The supplier table lists 12 / 36 kV rated-voltage options, 400 / 630 A rated-current options and 16(for 400A)/ 20(for 630A) kA rated short-circuit withstand current.

Номинальное напряжение
12 / 36 kV
Максимальный ток
400 / 630 A
Short-circuit withstand
16(for 400A)/ 20(for 630A) kA
Impulse withstand
95 / 170 kV

The supplier source lists IEC 62271-102:2001. Confirm the required standard edition, test documents and project acceptance scope before ordering.

Запросите обзор конфигурацииBrowse isolating switches

Published technical data

GW13-15 Isolating Switch Technical Parameters

The table below is transcribed from the target model’s authenticated WordPress source. Confirm the selected voltage, current, withstand level and accessory combination in the RFQ.

Электрические характеристики Спецификация Унита
Rated voltage of Disconnector 12 36 kV
Максимальный ток 400 / 630 A
Rated frequency 50 Hz
Lighting Impulse withstand voltage 95 170 kV
Power frequency withstand voltage in 1 min (Dry) 42 70 kV
Power frequency withstand voltage in 10 s  (Wet) 36 60 kV
Rated short circuit withstand current 16(for 400A)/ 20(for 630A) kA
Rated short circuit withstand time 3 s
Rated peak withstand current 40(for 400A)/ 50(for 630A) kA
Creepage 25 20 mm/kV
Blade stopped degree in opening position 90 Degree
Запасные части
Установка кронштейна с/без
Terminal clamp с/без
Loadbuster Hook с/без
Self locking Mechanism with
Материал
Terminal pads Brass/Copper plated by silver
Blade Copper plated by siliver
Изолятор Porcelain / Polymer
Channel Base Steel hot galvanized
Operating eye Brass
Пакет
Количество/пакет 1 ПК/бумага
Условия обслуживания
Максимальная температура окружающей среды 40 °C
Уровень загрязнения Heavy
Высота ≤1000 Метр
Стандартный IEC 62271-102:2001

Published source values include 50 Hz, 20 mm, 2001. Confirm the exact row and unit in the original technical table when preparing the RFQ.

Confirm system voltage, earthing arrangement, installation altitude, pollution level and required operating duty with the project engineer before final selection.

Список контрольных критериев отбора

Prepare the Isolating-Switch RFQ

  1. Define the system voltage. State nominal system voltage, rated voltage and insulation-coordination values.
  2. Match continuous and short-time duty. Confirm rated current, short-circuit withstand current, peak withstand current and duration.
  3. Choose the arrangement. Identify single-pole or three-pole construction, operating mechanism and rod length where applicable.
  4. Specify installation hardware. Confirm mounting bracket, terminal clamp, line connection, operating eye and crossarm arrangement.
  5. List documents and quantity. Include standard edition, drawings, test evidence, packing quantity, destination and required delivery schedule for quotation.

Configuration and supply boundary

Review the GW13-15 Configuration

The target source lists selectable hardware and material options. State each option explicitly so the quotation reflects the intended field installation.

Electrical coordination

Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.

Operating hardware

Depending on the model, specify operating mechanism, arcing-distinguishing chamber, operating rod length, loadbuster hook or self-locking mechanism.

Materials and corrosion protection

The source lists silver-plated copper terminals and blades, porcelain or polymer insulators and hot-galvanized steel bases. Confirm the selected combination.

Commercial boundary

Quantity, packaging, delivery schedule, private label and project documents remain subject to technical review and quotation.

Масштаб компании

Fuerte в общих чертах

FUERTE называет 1985 год годом основания, 220+ сотрудников и площадь здания 36 000 м². Эти данные, опубликованные поставщиками, дают представление о масштабах производства и поддержки проектов.

  • Операции на фабрике
  • Тестирование и инспекция
  • Поддержка экспорта

1985

Основанная в

Supplier-published company history

220+

Сотрудники

Published workforce scale

36,000 m²

Застроенная территория

Published manufacturing footprint

OEM

Поддержка ODM

Subject to technical review

О компании FUERTE

Возможность разработки и производства под заказ

Custom Support for Isolating-Switch Projects

FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.

  • Electrical configurationReview rated voltage, current, withstand values and service conditions for the target market.

  • Hardware selectionConfirm poles, operating mechanism, rod length, brackets, terminals and corrosion-resistant materials.

  • Project documentationState drawings, marking, packing, shipping marks and acceptance-document requirements before quotation.

Выставочный зал электротоваров FUERTE

Часто задаваемые вопросы

GW13-15 Isolating Switch FAQ

Which voltage and current values are published?

The target table lists 12 / 36 kV rated-voltage options and 400 / 630 A rated-current options. Confirm the exact configuration in the quotation.

What withstand values should be checked?

Review impulse withstand, power-frequency withstand, short-circuit withstand current and peak withstand current together with the insulation-coordination study.

Can the operating hardware be customized?

The source lists selectable mechanisms, brackets, terminals and, for some models, operating-rod length. Availability depends on technical review.

Что должно быть включено в запрос на предоставление предложения?

State model, poles, voltage, current, withstand duty, operating hardware, mounting arrangement, quantity, destination market and required documents.

Обзор конфигурации

Send the GW13-15 Requirements

Provide system voltage, rated current, short-circuit duty, insulation levels, pole arrangement, operating hardware, mounting details, quantity, destination market and required documents.