الرئيسية / المنتجات / قاطع مدار فراغي / Column Vacuum Circuit Breaker

قاطع مدار فراغي

قاطع الدائرة الفراغية العمودي

ZW32-12 series outdoor column vacuum circuit breaker (hereinafter referred to as circuit breaker) is distribution equipment of three-phase alternative current 50Hz which voltage rated at 12kV,it's mainly used for breaking and making load current, overload current, and short-circuit current in power system.It's suitable for use as protection and control in urban and rural power network, more suitable for places where are frequently operated.
نظرة عامة

محول الفراغ

Column Vacuum Circuit Breaker for Medium-Voltage Switching

Column Vacuum Circuit Breaker is presented for medium-voltage switching and protection projects. The authenticated supplier source provides product-specific construction notes and technical rows where published; use the exact model and installation duty for final selection.

Product family
Vacuum switching
Installation duty
Medium voltage
مقياس المرجع
Column
Final rating
تأكيد بالرسم

The page keeps the supplier’s model identity and source tables where available. Confirm the applicable IEC/GB standard, rated voltage, current, breaking capacity and project acceptance documents before ordering.

طلب مراجعة التكوينBrowse vacuum circuit breakers

Published technical data

Column Vacuum Circuit Breaker Technical Parameters

Use the source data below as the starting point for engineering review. Keep voltage class, continuous current, short-circuit duty, operating mechanism and installation environment together when selecting a breaker.

Published source table 1

الجهد المقنن كيلوفولت 12
1 min rated power-frequency withstand voltage كيلوفولت Phase to phase:42 Phase to ground:42 Fracture:48
Rated lightning impulse withstand voltage (peak value) كيلوفولت Phase to phase:75 Phase to ground:75 Fracture:85
التيار المقنن A 630
التردد المقدر هيرتز 50
Rated short-circuit breaking current KA 12.5 16 20
Rated short-circuit making current(peak value) كا 31.5 40 50
Rated peak withstand current كا 31.5 40 50
4s rated short-circuit withstand current KA 12.5 16 20
Rated operation sequence open-0.3s-close open-180s-close open
Closing time ms 25~60
Opening time ms 20~55
Rated short-circult breaking current breaking times times 30
Mechanical life times 10000
Second-time circuit 1 min power-frequency withstand voltage V 2000
Rated power of energy storoge motor W 40
Rated voltage of energy storage motor V DC220, 110
Rated closing operation voltage V DC220, 110 AC220
Rated opening operation voltage V DC220, 110 AC220
Motor energy storage time s ≤8

Published source table 2

Contact travel مم 9±1
Contact ultra travel مم 2±0.5
Central distance of interphase مم 340±1.5
Contact bouncing time on closing ms ≤ 2
Three-phase non-synchronous opening and closing ms ≤2
Average opening speed m/s 1.2±0.2
Average closing speed m/s 0.6±0.2
Conductive circuit resistance on each phase μΩ ≤ 80

Values shown are transcribed from the target listing where the authenticated source publishes them. Confirm the exact model row, unit, test condition and revision before using any value in a purchase specification.

قائمة التحقق من الاختيار

Specify the Vacuum Circuit Breaker for the Network

  1. Define the electrical duty. State rated voltage, continuous current, frequency, short-circuit breaking current, making current and insulation levels.
  2. Choose the construction. Confirm outdoor or indoor installation, common-box or pole-mounted arrangement, vacuum interrupter and insulation medium.
  3. Match the operating mechanism. Specify manual, motor or stored-energy operation, trip/close coil voltage, auxiliary contacts and control interface.
  4. Check the site environment. Provide altitude, ambient temperature, humidity, pollution, wind, seismic and enclosure requirements.
  5. قائمة الوثائق والكمية. Include drawings, wiring diagram, routine-test evidence, packing, destination market and delivery requirements in the RFQ.

الحدود الخاصة بالتكوين والإمداد

Review the Column Configuration

The supplier listing identifies a vacuum-circuit-breaker model family. State the exact model code and switching arrangement so the quotation does not mix ratings or accessories from another series.

Electrical parameters

Confirm rated voltage, current, frequency, short-circuit duty, insulation levels and operating sequence.

Mechanism and controls

Specify stored-energy mechanism, motor and coil voltages, auxiliary contacts, interlocks and local/remote control.

Structure and environment

Confirm pole arrangement, insulation housing, enclosure, altitude, temperature, pollution and installation interface.

الحدود التجارية

Quantity, packing, delivery schedule, private label and project documents remain subject to technical review and quotation.

حجم الشركة

فورتو بإيجاز

تُذكر FUERTE عام 1985 باعتباره عام تأسيسها، كما تُذكر وجود أكثر من 220 موظفاً وتخطيط مساحة تبلغ 36,000 متر مربع. وتوفر هذه الأرقام التي نشرها الموردون السياق اللازم لتصنيع المشروع ودعمه.

  • عمليات المصنع
  • التجربة والتفتيش
  • دعم التصدير

1985

تأسست في

تاريخ الشركة حسبما نشرته الشركة

220+

الموظفون

قياس القوة العاملة المنشورة

36,000 متر مربع

منطقة المبانى

التواجد المكتبي المعتمد

التصنيع باستخدام التصميم الخاص بالعميل

دعم ODM

خاضعاً لمراجعة فنية

عن FUERTE

قدرة التصنيع حسب الطلب (OEM) وODM

Custom Support for Vacuum-Breaker Projects

يتضمن نطاق أعمال FUERTE المطبوعة في مجال تصنيع المعدات الأصلية والتصنيع بالتوافق مع العلامة التجارية، تركيب الأجهزة، لوحات الاسم، التغليف، وعلامات الشحن.

  • Electrical configurationReview voltage class, current rating, insulation levels and service conditions.

  • واجهة ميكانيكيةConfirm pole structure, operating mechanism, fittings and mounting dimensions.

  • وثائق المشروعState drawings, wiring, marking, packing, shipping marks and acceptance-document requirements before quotation.

معرض منتجات كهربائية FUERTE

الأسئلة الشائعة

Column Vacuum Circuit Breaker FAQ

Which values should be matched first?

Start with rated voltage, continuous current, short-circuit breaking capacity, insulation levels, operating sequence and installation environment.

Are ratings interchangeable between vacuum-breaker series?

No. Confirm the exact model code and source table. Do not transfer ratings, dimensions or accessories from a similar-looking series.

Can the controls and fittings be customized?

تُصدر FUERTE نسخة من معدات التركيب ومواصفات المشروع كخدمة OEM/ODM. وتعتمد التوافر على المراجعة الفنية.

ما الذي يجب تضمينه في طلب عرض الأسعار؟

State model, rated voltage, current, breaking duty, mechanism and coil voltages, mounting interface, quantity, destination and required documents.

استعراض التكوين

Send the Column Requirements

Provide rated voltage, current, breaking duty, insulation levels, mechanism, dimensions, mounting details, quantity, destination market and required documents.