الرئيسية / المنتجات / قاطع مدار فراغي / ZW20-12/630-20 Vacuum Circuit Breaker

قاطع مدار فراغي

ZW20-12/630-20 مفتاح مغلق دوار فراغي

نظرة عامة

محول الفراغ

ZW20-12/630-20 Vacuum Circuit Breaker for Medium-Voltage Switching

ZW20-12/630-20 Vacuum Circuit Breaker is presented for medium-voltage switching and protection projects. The authenticated supplier source provides product-specific construction notes and technical rows where published; use the exact model and installation duty for final selection.

Product family
Vacuum switching
Installation duty
Medium voltage
مقياس المرجع
ZW20-12/630-20
Final rating
تأكيد بالرسم

The page keeps the supplier’s model identity and source tables where available. Confirm the applicable IEC/GB standard, rated voltage, current, breaking capacity and project acceptance documents before ordering.

طلب مراجعة التكوينBrowse vacuum circuit breakers

Published technical data

ZW20-12/630-20 Vacuum Circuit Breaker Technical Parameters

Use the source data below as the starting point for engineering review. Keep voltage class, continuous current, short-circuit duty, operating mechanism and installation environment together when selecting a breaker.

Published source table 1

No Descriptions unit Standard parameter values
1.1 قاطع مدار فراغي
1.1.1 Model No ZW20-12
1.1.2 Switching structure Transformer form External or internal
Insulating Material A:Epoxy resin outsourced silicone rubber
B:Outdoor epoxy resin
1.1.3 Insulating and extinguishing media SF6, Vacuum
1.1.4 Rated Voltage كيلوفولت 12
1.1.5 Rated Current A 630
1.1.6 Rated cable charging and breaking current A 20
1.1.7 Rated short-circuit breaking current كا 12.5, 16, 20
1.1.8 Temperature rise test current 1.1Ir
1.1.9 Rated frequency 1 min withstand voltage To earth/Between كيلوفولت 42
Across the base كيلوفولت 48
1.1.10 Rated lightning impulse withstand voltage(1.2/50μs)Peak value To earth/Between كيلوفولت 75
Across the base كيلوفولت 85
1.1.11 Rated short-time withstand current and duration kA/s 20/3
1.1.12 Rated peak withstand current كا 50
1.1.13 Rated short-circuit breaking current كا 20
1.1.14 Rated short-circuit closing current كا 50
1.1.15 Main circuit resistance μΩ 80
1.1.16 Mechanical stability times ≥10000 No load
1.1.17 Minimum creepage distance for external insulation مم 372
1.1.18 Rated short-circuit breaking current breaking times times ≥30times
1.1.19 Closing and opening not synchronized ms ≤2
1.1.20 Contact closing bounce time ms ≤2
1.1.21 Partial discharge(1.1Ur) pC ≤20
1.2 Operating Mechanism
1.2.1 Type or model of actuator Spring or permanent magnet mechanism
1.2.2 Operating Method Motorized with manual operation
1.2.3 Motor Voltage V Conventional DC220
1.2.4 Auxiliary contact capacity DC24V、10A
1.2.5 DC resistance of telecommunication circuit After 100times operations<1Ω
1.3 Transformer combination mode Includes current transformers, electronic zero sequence voltage transformers, and electromagnetic voltage transformers or other models..
1.4 Current Transformer
1.4.1 Rated current ratio (1) Phase current: 600A/5A

(2) Zero sequence current: 100A/1A

1.4.2 Accuracy Level (1) phase current: protection class 5P10

(2) Zero sequence current: use 100A/1A

Protection Class 10P30.

1.4.3 Implementation method Electromagnetic
1.4.4 Temperature range -40℃~70℃
1.5 Electromagnetic voltage transformers
1.5.1 Rated Voltage Ratio Zero sequence voltage: (10kV/)/( 6.5V/3)
1.5.2 Accuracy Level Zero sequence voltage: 3P level
1.5.3 Temperature range  -40℃~70℃
1.5.4 Partial discharge Pc ≤20 (1.1Um)
1.5.5 Load Impedance ≥2MΩ
1.6 Electromagnetic voltage transformers (external)
1.6.1 Quantities Pc 1 or 2 optional
1.6.2 Rated Voltage Ratio Line voltage measurement: 10kV/0.1kV

Supply voltage: 10kV/0.22kV

1.6.3 Accuracy level Measuring voltage winding: 0.5 level

Supply voltage winding: 3 levels

1.6.4 Capacity (VA) Measuring voltage winding: ≥10VA

Supply voltage winding: long-term capacity ≥ 50VA, short-time capacity ≥ 300VA/30s

1.7 Mechanical property
1.7.1 contact opening distance مم 9±1
1.7.2 contact overtravel مم 3.5±0.5
1.7.3 Average closing speed m/s 0.4-0.8
1.7.4 Average gate opening speed m/s 1.0-1.4
1.7.5 Closing time مم ≤60
1.7.6 Split time Ms   ≤ 45
1.7.7 Closing Bounce Time Ms  ≤2
1.7.8 Three-phase switching non-synchronous Ms  ≤2
1.7.9 Interphase center distance مم 280 ±1.5
1.8 Enclosure protection class Not less than IP65
1.10 Box Material 304 or hot rolled steel Support for surface treatment
1.11 Secondary equipment
1.11.1 Intelligent Control Terminal Support remote local, three protection, three remote, reclosing, SOE, can also be equipped with the statute of the communication connection backstage real-time monitoring, adjusting, issuing fixed value and other configurations, other requirements to inform when ordering One or two times are connected by aviation plug-in, without external wiring.

Values shown are transcribed from the target listing where the authenticated source publishes them. Confirm the exact model row, unit, test condition and revision before using any value in a purchase specification.

قائمة التحقق من الاختيار

Specify the Vacuum Circuit Breaker for the Network

  1. Define the electrical duty. State rated voltage, continuous current, frequency, short-circuit breaking current, making current and insulation levels.
  2. Choose the construction. Confirm outdoor or indoor installation, common-box or pole-mounted arrangement, vacuum interrupter and insulation medium.
  3. Match the operating mechanism. Specify manual, motor or stored-energy operation, trip/close coil voltage, auxiliary contacts and control interface.
  4. Check the site environment. Provide altitude, ambient temperature, humidity, pollution, wind, seismic and enclosure requirements.
  5. قائمة الوثائق والكمية. Include drawings, wiring diagram, routine-test evidence, packing, destination market and delivery requirements in the RFQ.

الحدود الخاصة بالتكوين والإمداد

Review the ZW20-12/630-20 Configuration

The supplier listing identifies a vacuum-circuit-breaker model family. State the exact model code and switching arrangement so the quotation does not mix ratings or accessories from another series.

Electrical parameters

Confirm rated voltage, current, frequency, short-circuit duty, insulation levels and operating sequence.

Mechanism and controls

Specify stored-energy mechanism, motor and coil voltages, auxiliary contacts, interlocks and local/remote control.

Structure and environment

Confirm pole arrangement, insulation housing, enclosure, altitude, temperature, pollution and installation interface.

الحدود التجارية

Quantity, packing, delivery schedule, private label and project documents remain subject to technical review and quotation.

حجم الشركة

فورتو بإيجاز

تُذكر FUERTE عام 1985 باعتباره عام تأسيسها، كما تُذكر وجود أكثر من 220 موظفاً وتخطيط مساحة تبلغ 36,000 متر مربع. وتوفر هذه الأرقام التي نشرها الموردون السياق اللازم لتصنيع المشروع ودعمه.

  • عمليات المصنع
  • التجربة والتفتيش
  • دعم التصدير

1985

تأسست في

تاريخ الشركة حسبما نشرته الشركة

220+

الموظفون

قياس القوة العاملة المنشورة

36,000 متر مربع

منطقة المبانى

التواجد المكتبي المعتمد

التصنيع باستخدام التصميم الخاص بالعميل

دعم ODM

خاضعاً لمراجعة فنية

عن FUERTE

قدرة التصنيع حسب الطلب (OEM) وODM

Custom Support for Vacuum-Breaker Projects

يتضمن نطاق أعمال FUERTE المطبوعة في مجال تصنيع المعدات الأصلية والتصنيع بالتوافق مع العلامة التجارية، تركيب الأجهزة، لوحات الاسم، التغليف، وعلامات الشحن.

  • Electrical configurationReview voltage class, current rating, insulation levels and service conditions.

  • واجهة ميكانيكيةConfirm pole structure, operating mechanism, fittings and mounting dimensions.

  • وثائق المشروعState drawings, wiring, marking, packing, shipping marks and acceptance-document requirements before quotation.

معرض منتجات كهربائية FUERTE

الأسئلة الشائعة

ZW20-12/630-20 Vacuum Circuit Breaker FAQ

Which values should be matched first?

Start with rated voltage, continuous current, short-circuit breaking capacity, insulation levels, operating sequence and installation environment.

Are ratings interchangeable between vacuum-breaker series?

No. Confirm the exact model code and source table. Do not transfer ratings, dimensions or accessories from a similar-looking series.

Can the controls and fittings be customized?

تُصدر FUERTE نسخة من معدات التركيب ومواصفات المشروع كخدمة OEM/ODM. وتعتمد التوافر على المراجعة الفنية.

ما الذي يجب تضمينه في طلب عرض الأسعار؟

State model, rated voltage, current, breaking duty, mechanism and coil voltages, mounting interface, quantity, destination and required documents.

استعراض التكوين

Send the ZW20-12/630-20 Requirements

Provide rated voltage, current, breaking duty, insulation levels, mechanism, dimensions, mounting details, quantity, destination market and required documents.