مفتاح عزل

مفتاح عزل

RH-B Isolating Switch

Disconnect switch / isolating switch is divided into single-pole and three-pole type, porcelain,polymer and resin type,standard and loadbreak type, which used for outdoor alternative current distribution electric system. For rated frequency 50Hz. Technical Standard:IEC60694, IEC62271-102 latest standard
نظرة عامة

Medium-voltage isolating switch

RH-B Isolating Switch for Medium-Voltage Distribution Isolation

RH-B is an isolating-switch family with three-pole and single-pole configurations. The supplier tables list 11–36 kV ratings, up to 630 A for RH-B and up to 1,250 A for the GW three-pole variant, plus 15–36 kV single-pole options.

الجهد المقنن
11–36 kV
التيار المقنن
630 / 1250 A
Short-circuit withstand
12.5–20 kA
Impulse withstand
95–195 kV

The RH-B source page does not publish a standard edition; confirm the applicable standard, test documents and project acceptance scope before ordering.

طلب مراجعة التكوينBrowse isolating switches

Published technical data

RH-B Isolating Switch Technical Parameters

The source publishes separate three-pole and single-pole tables. They are reproduced below so buyers can compare voltage, current, withstand and leakage-distance rows without mixing configurations.

Published table 1

نموذج Rated Voltage Rated Current Max 4s Heat Steady e.c. Impulse Withstand Voltage Power-frequency Withstand Voltage Leakage Distance
كيلوفولت A كا كيلوفولت كيلوفولت مم
RH-B 11 630 12.5 95 42 420
RH-B 33 630 12.5 195 80 680

Published table 2

نموذج Rated Voltage Rated Current Max 4s Heat Steady e.c. Impulse Withstand Voltage Power-frequency Withstand Voltage Leakage Distance
كيلوفولت A كا كيلوفولت كيلوفولت مم
GW 11 1250 12.5 95 42 420
33 1250 12.5 195 80 680

Published table 3

نموذج Rated Voltage Rated Current Max Short-time Withstand Current Peak Value Withstand Current Impulse Withstand Voltage Power-frequency Withstand Voltage Leakage Distance
كيلوفولت A kA/s كيلوفولت كيلوفولت كيلوفولت مم
FGW11-12/630 27 630 20/2 50 125 45 510

Published table 4

نموذج Rated Voltage Rated Current Max 4s Heat Steady Dynamic Steady Current Impulse Withstand Voltage Power-frequency Withstand Voltage
كيلوفولت A كا كا كيلوفولت كيلوفولت
GW-15 15 630 20 50 95 42
GW-27 27 630 20 50 125 65
GW-36 36 630 20 50 170 75

Published table 5

نموذج Rated Voltage Rated Current Max 4s Heat Steady Dynamic Steady Current Impulse Withstand Voltage Power-frequency Withstand Voltage
كيلوفولت A كا كا كيلوفولت كيلوفولت
FGW10 15 630 20 50 95 42
27 630 20 50 125 65
36 630 20 50 170 75

Confirm system voltage, earthing arrangement, installation altitude, pollution level and required operating duty with the project engineer before final selection.

قائمة التحقق من الاختيار

Prepare the Isolating-Switch RFQ

  1. Define the system voltage. State nominal system voltage, rated voltage and insulation-coordination values.
  2. Match continuous and short-time duty. Confirm rated current, short-circuit withstand current, peak withstand current and duration.
  3. Choose the arrangement. Identify single-pole or three-pole construction, operating mechanism and rod length where applicable.
  4. Specify installation hardware. Confirm mounting bracket, terminal clamp, line connection, operating eye and crossarm arrangement.
  5. قائمة الوثائق والكمية. Include standard edition, drawings, test evidence, packing quantity, destination and required delivery schedule for quotation.

الحدود الخاصة بالتكوين والإمداد

Review the RH-B Configuration

The target source lists selectable hardware and material options. State each option explicitly so the quotation reflects the intended field installation.

Electrical coordination

Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.

Operating hardware

Depending on the model, specify operating mechanism, arcing-distinguishing chamber, operating rod length, loadbuster hook or self-locking mechanism.

Materials and corrosion protection

The source lists silver-plated copper terminals and blades, porcelain or polymer insulators and hot-galvanized steel bases. Confirm the selected combination.

الحدود التجارية

Quantity, packaging, delivery schedule, private label and project documents remain subject to technical review and quotation.

حجم الشركة

فورتو بإيجاز

تُذكر FUERTE عام 1985 باعتباره عام تأسيسها، كما تُذكر وجود أكثر من 220 موظفاً وتخطيط مساحة تبلغ 36,000 متر مربع. وتوفر هذه الأرقام التي نشرها الموردون السياق اللازم لتصنيع المشروع ودعمه.

  • عمليات المصنع
  • التجربة والتفتيش
  • دعم التصدير

1985

تأسست في

تاريخ الشركة حسبما نشرته الشركة

220+

الموظفون

قياس القوة العاملة المنشورة

36,000 متر مربع

منطقة المبانى

التواجد المكتبي المعتمد

التصنيع باستخدام التصميم الخاص بالعميل

دعم ODM

خاضعاً لمراجعة فنية

عن FUERTE

قدرة التصنيع حسب الطلب (OEM) وODM

Custom Support for Isolating-Switch Projects

يتضمن نطاق أعمال FUERTE المطبوعة في مجال تصنيع المعدات الأصلية والتصنيع بالتوافق مع العلامة التجارية، تركيب الأجهزة، لوحات الاسم، التغليف، وعلامات الشحن.

  • Electrical configurationReview rated voltage, current, withstand values and service conditions for the target market.

  • Hardware selectionConfirm poles, operating mechanism, rod length, brackets, terminals and corrosion-resistant materials.

  • وثائق المشروعتقديم رسومات الدولة وتحديد المواقع والتعبئة والشحن والاحتياجات من مستندات القبول قبل تقديم العرض.

معرض منتجات كهربائية FUERTE

الأسئلة الشائعة

RH-B Isolating Switch FAQ

Which voltage and current values are published?

The target table lists 11–36 kV rated-voltage options and 630 / 1250 A rated-current options. Confirm the exact configuration in the quotation.

What withstand values should be checked?

Review impulse withstand, power-frequency withstand, short-circuit withstand current and peak withstand current together with the insulation-coordination study.

Can the operating hardware be customized?

The source lists selectable mechanisms, brackets, terminals and, for some models, operating-rod length. Availability depends on technical review.

ما الذي يجب تضمينه في طلب عرض الأسعار؟

State model, poles, voltage, current, withstand duty, operating hardware, mounting arrangement, quantity, destination market and required documents.

استعراض التكوين

Send the RH-B Requirements

Provide system voltage, rated current, short-circuit duty, insulation levels, pole arrangement, operating hardware, mounting details, quantity, destination market and required documents.