Electrical coordination
Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.
Medium-voltage isolating switch
RH-B is an isolating-switch family with three-pole and single-pole configurations. The supplier tables list 11–36 kV ratings, up to 630 A for RH-B and up to 1,250 A for the GW three-pole variant, plus 15–36 kV single-pole options.
The RH-B source page does not publish a standard edition; confirm the applicable standard, test documents and project acceptance scope before ordering.
Published technical data
The source publishes separate three-pole and single-pole tables. They are reproduced below so buyers can compare voltage, current, withstand and leakage-distance rows without mixing configurations.
| نموذج | Rated Voltage | Rated Current Max | 4s Heat Steady e.c. | Impulse Withstand Voltage | Power-frequency Withstand Voltage | Leakage Distance |
| كيلوفولت | A | كا | كيلوفولت | كيلوفولت | مم | |
| RH-B | 11 | 630 | 12.5 | 95 | 42 | 420 |
| RH-B | 33 | 630 | 12.5 | 195 | 80 | 680 |
| نموذج | Rated Voltage | Rated Current Max | 4s Heat Steady e.c. | Impulse Withstand Voltage | Power-frequency Withstand Voltage | Leakage Distance |
| كيلوفولت | A | كا | كيلوفولت | كيلوفولت | مم | |
| GW | 11 | 1250 | 12.5 | 95 | 42 | 420 |
| 33 | 1250 | 12.5 | 195 | 80 | 680 |
| نموذج | Rated Voltage | Rated Current Max | Short-time Withstand Current | Peak Value Withstand Current | Impulse Withstand Voltage | Power-frequency Withstand Voltage | Leakage Distance |
| كيلوفولت | A | kA/s | كيلوفولت | كيلوفولت | كيلوفولت | مم | |
| FGW11-12/630 | 27 | 630 | 20/2 | 50 | 125 | 45 | 510 |
| نموذج | Rated Voltage | Rated Current Max | 4s Heat Steady | Dynamic Steady Current | Impulse Withstand Voltage | Power-frequency Withstand Voltage |
| كيلوفولت | A | كا | كا | كيلوفولت | كيلوفولت | |
| GW-15 | 15 | 630 | 20 | 50 | 95 | 42 |
| GW-27 | 27 | 630 | 20 | 50 | 125 | 65 |
| GW-36 | 36 | 630 | 20 | 50 | 170 | 75 |
| نموذج | Rated Voltage | Rated Current Max | 4s Heat Steady | Dynamic Steady Current | Impulse Withstand Voltage | Power-frequency Withstand Voltage |
| كيلوفولت | A | كا | كا | كيلوفولت | كيلوفولت | |
| FGW10 | 15 | 630 | 20 | 50 | 95 | 42 |
| 27 | 630 | 20 | 50 | 125 | 65 | |
| 36 | 630 | 20 | 50 | 170 | 75 |
Confirm system voltage, earthing arrangement, installation altitude, pollution level and required operating duty with the project engineer before final selection.
قائمة التحقق من الاختيار
الحدود الخاصة بالتكوين والإمداد
The target source lists selectable hardware and material options. State each option explicitly so the quotation reflects the intended field installation.
Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.
Depending on the model, specify operating mechanism, arcing-distinguishing chamber, operating rod length, loadbuster hook or self-locking mechanism.
The source lists silver-plated copper terminals and blades, porcelain or polymer insulators and hot-galvanized steel bases. Confirm the selected combination.
Quantity, packaging, delivery schedule, private label and project documents remain subject to technical review and quotation.



حجم الشركة
تُذكر FUERTE عام 1985 باعتباره عام تأسيسها، كما تُذكر وجود أكثر من 220 موظفاً وتخطيط مساحة تبلغ 36,000 متر مربع. وتوفر هذه الأرقام التي نشرها الموردون السياق اللازم لتصنيع المشروع ودعمه.
1985
تاريخ الشركة حسبما نشرته الشركة
220+
قياس القوة العاملة المنشورة
36,000 متر مربع
التواجد المكتبي المعتمد
التصنيع باستخدام التصميم الخاص بالعميل
خاضعاً لمراجعة فنية
قدرة التصنيع حسب الطلب (OEM) وODM
يتضمن نطاق أعمال FUERTE المطبوعة في مجال تصنيع المعدات الأصلية والتصنيع بالتوافق مع العلامة التجارية، تركيب الأجهزة، لوحات الاسم، التغليف، وعلامات الشحن.
Electrical configurationReview rated voltage, current, withstand values and service conditions for the target market.
Hardware selectionConfirm poles, operating mechanism, rod length, brackets, terminals and corrosion-resistant materials.
وثائق المشروعتقديم رسومات الدولة وتحديد المواقع والتعبئة والشحن والاحتياجات من مستندات القبول قبل تقديم العرض.

الأسئلة الشائعة
The target table lists 11–36 kV rated-voltage options and 630 / 1250 A rated-current options. Confirm the exact configuration in the quotation.
Review impulse withstand, power-frequency withstand, short-circuit withstand current and peak withstand current together with the insulation-coordination study.
The source lists selectable mechanisms, brackets, terminals and, for some models, operating-rod length. Availability depends on technical review.
State model, poles, voltage, current, withstand duty, operating hardware, mounting arrangement, quantity, destination market and required documents.
استعراض التكوين
Provide system voltage, rated current, short-circuit duty, insulation levels, pole arrangement, operating hardware, mounting details, quantity, destination market and required documents.
هل ترغب في الحصول على هذا المنتج؟ قم بتعبئة النموذج أدناه وسيقوم فريق المبيعات لدينا بالرد عليك في غضون 24 ساعة.
لا تتردد في ترك رسالة للاستشارة. سنقدم لك المزيد من خيارات الخدمة.