Electrical coordination
Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.
Medium-voltage isolating switch
RH-B is an isolating-switch family with three-pole and single-pole configurations. The supplier tables list 11–36 kV ratings, up to 630 A for RH-B and up to 1,250 A for the GW three-pole variant, plus 15–36 kV single-pole options.
The RH-B source page does not publish a standard edition; confirm the applicable standard, test documents and project acceptance scope before ordering.
Demander une révision de la configurationBrowse isolating switches
Published technical data
The source publishes separate three-pole and single-pole tables. They are reproduced below so buyers can compare voltage, current, withstand and leakage-distance rows without mixing configurations.
| Model | Rated Voltage | Rated Current Max | 4s Heat Steady e.c. | Impulse Withstand Voltage | Power-frequency Withstand Voltage | Leakage Distance |
|---|---|---|---|---|---|---|
| kV | A | kA | kV | kV | mm | |
| RH-B | 11 | 630 | 12.5 | 95 | 42 | 420 |
| RH-B | 33 | 630 | 12.5 | 195 | 80 | 680 |
| Model | Rated Voltage | Rated Current Max | 4s Heat Steady e.c. | Impulse Withstand Voltage | Power-frequency Withstand Voltage | Leakage Distance |
|---|---|---|---|---|---|---|
| kV | A | kA | kV | kV | mm | |
| GW | 11 | 1250 | 12.5 | 95 | 42 | 420 |
| 33 | 1250 | 12.5 | 195 | 80 | 680 |
| Model | Rated Voltage | Rated Current Max | Short-time Withstand Current | Peak Value Withstand Current | Impulse Withstand Voltage | Power-frequency Withstand Voltage | Leakage Distance |
|---|---|---|---|---|---|---|---|
| kV | A | kA/s | kV | kV | kV | mm | |
| FGW11-12/630 | 27 | 630 | 20/2 | 50 | 125 | 45 | 510 |
| Model | Rated Voltage | Rated Current Max | 4s Heat Steady | Dynamic Steady Current | Impulse Withstand Voltage | Power-frequency Withstand Voltage |
|---|---|---|---|---|---|---|
| kV | A | kA | kA | kV | kV | |
| GW-15 | 15 | 630 | 20 | 50 | 95 | 42 |
| GW-27 | 27 | 630 | 20 | 50 | 125 | 65 |
| GW-36 | 36 | 630 | 20 | 50 | 170 | 75 |
| Model | Rated Voltage | Rated Current Max | 4s Heat Steady | Dynamic Steady Current | Impulse Withstand Voltage | Power-frequency Withstand Voltage |
|---|---|---|---|---|---|---|
| kV | A | kA | kA | kV | kV | |
| FGW10 | 15 | 630 | 20 | 50 | 95 | 42 |
| 27 | 630 | 20 | 50 | 125 | 65 | |
| 36 | 630 | 20 | 50 | 170 | 75 |
Confirm system voltage, earthing arrangement, installation altitude, pollution level and required operating duty with the project engineer before final selection.
Liste de contrôle de sélection
Configuration and supply boundary
The target source lists selectable hardware and material options. State each option explicitly so the quotation reflects the intended field installation.
Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.
Depending on the model, specify operating mechanism, arcing-distinguishing chamber, operating rod length, loadbuster hook or self-locking mechanism.
The source lists silver-plated copper terminals and blades, porcelain or polymer insulators and hot-galvanized steel bases. Confirm the selected combination.
Quantity, packaging, delivery schedule, private label and project documents remain subject to technical review and quotation.
Taille de l'entreprise
FUERTE indique 1985 comme année de fondation, plus de 220 employés et une superficie bâtie de 36 000 m². Ces chiffres publiés par le fournisseur fournissent un contexte pour la fabrication et le support de projets.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
Capacité OEM & ODM
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview rated voltage, current, withstand values and service conditions for the target market.
Hardware selectionConfirm poles, operating mechanism, rod length, brackets, terminals and corrosion-resistant materials.
Project documentationState drawings, marking, packing, shipping marks and acceptance-document requirements before quotation.

Foire aux questions
The target table lists 11–36 kV rated-voltage options and 630 / 1250 A rated-current options. Confirm the exact configuration in the quotation.
Review impulse withstand, power-frequency withstand, short-circuit withstand current and peak withstand current together with the insulation-coordination study.
The source lists selectable mechanisms, brackets, terminals and, for some models, operating-rod length. Availability depends on technical review.
State model, poles, voltage, current, withstand duty, operating hardware, mounting arrangement, quantity, destination market and required documents.
Examen de la configuration
Provide system voltage, rated current, short-circuit duty, insulation levels, pole arrangement, operating hardware, mounting details, quantity, destination market and required documents.
Ce produit vous intéresse ? Remplissez le formulaire ci-dessous et notre équipe commerciale vous recontactera dans les 24 heures.
N'hésitez pas à laisser un message pour consultation. Nous vous proposerons davantage d'options de service.