Electrical coordination
Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.
Metal oxide surge arrester
The supplier table identifies Y5(10W)-36 as a 36 kV, 50 Hz, gapless Design B distribution-type surge arrester with 5 / 10 kA nominal discharge-current options and 29 kV maximum continuous operating voltage.
The source lists IEC60099-4:2014. Confirm the required standard edition, arrester class and project acceptance documents before ordering.
Published technical data
Review the published electrical characteristics together with the selectable accessories, material options, package information and service conditions.
| Parameter | Published value | Unit |
|---|---|---|
| Rated voltage of Surge arrreser | 36 | kV |
| Nominal discharge current | 5 / 10 | kA |
| Rated frequency | 50 | Hz |
| Maximum continuous operating voltage | 29 | kV |
| Steep current impulse residual voltage | 123 | kV(Crest) |
| Lightning Impulse residual voltage | 108 | kV(Crest) |
| Switching Impulse residual voltage | 92.4 | kV(Crest) |
| Long duration current impulse withstand voltage | 150 / 250 | A |
| High current impulses | 65 / 100 | kA (Crest) |
| Rated Short-circuit current | 20 / 12 / 6 / 0.6 ± 0.2 | kA |
| Class of Surge arrester | Class 1 or Class 2 | |
| Application | Distribution type | |
| With or without gap | Gapless | |
| Designation of arrester | Design B | |
| Spare parts | ||
| NEMA A or B mounting bracket | with/without | |
| Disconnector | with/without | |
| Earth lead | with/without | |
| Bird guard cap | with/without | |
| Line clamp | with/without | |
| Upper terminal (incoming line) bolt size | M12 | |
| Lower termina (outgoing line) bolt size | M10 | |
| Material | ||
| Upper terminal | Stainless steel 304 | |
| Housing | Polymer type | |
| Color of housing | Dark grey / light grey | |
| Varistor | High quality zinc oxide varistor | |
| Size of Varistor | 35mm / 38mm /40mm / 42mm | |
| Package | ||
| Qty/package | 3 | pc/carton |
| Service conditions | ||
| Environment maximum temperature | 40 | ℃ |
| Pollution level | Heavy | |
| Altitude | 1000 | Meter |
| Standard | IEC60099-4:2014 | |
Confirm the selected rating against the system voltage, earthing arrangement, insulation coordination, installation altitude and pollution conditions.
Selection checklist
Configuration and supply boundary
The supplier table lists a polymer housing, Grade 304 stainless steel upper terminal and zinc oxide varistor options sized 35mm / 38mm /40mm / 42mm.
Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.
State bracket pattern, terminal connection, line clamp and earth-lead requirements in the inquiry.
Confirm whether the supply should include a disconnector, insulating base, counter or monitor.
Quantity, packing, delivery schedule, test documents and destination requirements depend on quotation.
Company scale
FUERTE lists 1985 as its founding year, 220+ employees and a 36,000 m² built-up area. These supplier-published figures provide context for manufacturing and project support.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
OEM & ODM capability
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview rated voltage, MCOV, discharge current, residual voltage and service conditions.
Hardware selectionConfirm brackets, terminals, disconnectors, bird guards, counters and monitors.
Project documentationState drawing, marking, packing and acceptance-document requirements before quotation.

Frequently asked questions
The table lists 36 kV rated voltage and 29 kV maximum continuous operating voltage.
The published steep-current, lightning-impulse and switching-impulse residual voltages are 123 kV, 108 kV and 92.4 kV crest respectively.
The source identifies the product as a gapless, Design B, distribution-type arrester.
State the system voltage, MCOV, nominal discharge current, residual-voltage limits, short-circuit requirement, mounting hardware, disconnector, terminal sizes, quantity and destination market.
Configuration review
Provide system voltage, arrester rated voltage, MCOV, nominal discharge current, residual-voltage limits, mounting and accessory requirements, quantity, destination market and required documents.