Electrical coordination
Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.
Medium-voltage isolating switch
RH-B Isolating Switch is a medium-voltage isolating switch for outdoor distribution isolation. The supplier table lists 12 / 36 kV rated-voltage options, 200 / 400 / 630 A rated-current options and 12.5(for 400A) / 16 (for 630A) kA rated short-circuit withstand current.
The supplier source lists IEC 62271-102:2001. Confirm the required standard edition, test documents and project acceptance scope before ordering.
Published technical data
The table below is transcribed from the target model’s authenticated WordPress source. Confirm the selected voltage, current, withstand level and accessory combination in the RFQ.
| Электрические характеристики | Спецификация | Унита | |
|---|---|---|---|
| Rated voltage of Disconnector | 12 | 36 | kV |
| Максимальный ток | 200 / 400 / 630 | A | |
| Rated frequency | 50 | Hz | |
| Lighting Impulse withstand voltage | 95 | 170 | kV |
| Power frequency withstand voltage in 1 min (Dry) | 42 | 70 | kV |
| Power frequency withstand voltage in 10 s (Wet) | 36 | 60 | kV |
| Rated short circuit withstand current | 12.5(for 400A) / 16 (for 630A) | kA | |
| Rated short circuit withstand time | 3 | s | |
| Rated peak withstand current | 31.5(for 400A) / 40(for 630A) | kA | |
| Creepage | 20 or 31 | mm/kV | |
| Запасные части | |||
| Operating Mechanism | with | ||
| Arcing distinguishing chamber | с/без | ||
| Operating rod length | Customerized | ||
| Материал | |||
| Terminal pads | Copper plated by silver | ||
| Blade | Copper plated by siliver | ||
| Изолятор | Porcelain / Polymer | ||
| Channel Base | Steel hot galvanized | ||
| Пакет | |||
| Количество/пакет | 1 | pc/case | |
| Условия обслуживания | |||
| Максимальная температура окружающей среды | 40 | °C | |
| Уровень загрязнения | Heavy | ||
| Высота | 1000 | Метр | |
| Стандартный | IEC 62271-102:2001 | ||
Published source values include 50 Hz, 31 mm, 2001. Confirm the exact row and unit in the original technical table when preparing the RFQ.
Confirm system voltage, earthing arrangement, installation altitude, pollution level and required operating duty with the project engineer before final selection.
Список контрольных критериев отбора
Configuration and supply boundary
The target source lists selectable hardware and material options. State each option explicitly so the quotation reflects the intended field installation.
Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.
Depending on the model, specify operating mechanism, arcing-distinguishing chamber, operating rod length, loadbuster hook or self-locking mechanism.
The source lists silver-plated copper terminals and blades, porcelain or polymer insulators and hot-galvanized steel bases. Confirm the selected combination.
Quantity, packaging, delivery schedule, private label and project documents remain subject to technical review and quotation.



Масштаб компании
FUERTE называет 1985 год годом основания, 220+ сотрудников и площадь здания 36 000 м². Эти данные, опубликованные поставщиками, дают представление о масштабах производства и поддержки проектов.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
Возможность разработки и производства под заказ
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview rated voltage, current, withstand values and service conditions for the target market.
Hardware selectionConfirm poles, operating mechanism, rod length, brackets, terminals and corrosion-resistant materials.
Project documentationState drawings, marking, packing, shipping marks and acceptance-document requirements before quotation.

Часто задаваемые вопросы
The target table lists 12 / 36 kV rated-voltage options and 200 / 400 / 630 A rated-current options. Confirm the exact configuration in the quotation.
Review impulse withstand, power-frequency withstand, short-circuit withstand current and peak withstand current together with the insulation-coordination study.
The source lists selectable mechanisms, brackets, terminals and, for some models, operating-rod length. Availability depends on technical review.
State model, poles, voltage, current, withstand duty, operating hardware, mounting arrangement, quantity, destination market and required documents.
Обзор конфигурации
Provide system voltage, rated current, short-circuit duty, insulation levels, pole arrangement, operating hardware, mounting details, quantity, destination market and required documents.
Интересует этот товар? Заполните форму ниже, и наш продакт-менеджмент свяжется с вами в течение 24 часов.
Пожалуйста, оставляйте сообщения для консультации. Мы предложим вам больше вариантов обслуживания.