Молниеотвод
Главная / Продукты / Молниеотвод / Y5(10)C-11 Surge Arrester

Молниеотвод

Y5(10)C-11 Устройство защиты от перегрузок

  • The surge arrester is assembled above overhead distribution transformers, where they shunt the energy from overvoltage events (especially lightning effects) to a ground connection and protect the equipment against damage in system.
  • Характеристика:
  • Voltage: 11kV
  • Current: 5kA / 10kA
  • Application: Overhead Distribution Line
  • Standard: IEC60099-4
Обзор

Metal oxide surge arrester

Y5(10)C-11 Surge Arrester for Distribution Overvoltage Protection

The supplier table identifies Y5(10)C-11 as a 11 kV, 50 Hz, gapless Design B distribution-type surge arrester with 5 / 10 kA nominal discharge-current options and 9.4 kV maximum continuous operating voltage.

Номинальное напряжение
11 kV
Nominal discharge current
5 / 10 kA
MCOV
9.4 kV
Published standard
IEC60099-4:2014

The source lists IEC60099-4:2014. Confirm the required standard edition, arrester class and project acceptance documents before ordering.

Запросите обзор конфигурацииBrowse lightning arresters

Published technical data

Y5(10)C-11 Technical Parameters

Review the published electrical characteristics together with the selectable accessories, material options, package information and service conditions.

Электрические характеристики Спецификация Унита
Rated voltage of Surge arrreser 11 kV
Nominal discharge current 5 10 kA
Rated frequency 50 Hz
Maximum continuous operating voltage 9.4 kV
Steep current impulse residual voltage 40 kV(Crest)
Lightning Impulse residual voltage 33 kV(Crest)
Switching Impulse residual voltage 30 kV(Crest)
Long duration current impulse

withstand voltage

150 250 A
High current impulses 65 100 kA (Crest)
Rated Short-circuit current 20 / 12 / 6 / 0.6 ± 0.2 kA
Class of Surge arrester Class 1 or Class 2
Приложение Distribution type
With or without gap Gapless
Designation of arrester Design B
Запасные части
NEMA A or B mounting bracket с/без
Отключающий элемент с/без
Earth lead с/без
Bird guard cap с/без
Line clamp с/без
Upper terminal (incoming line) bolt size M12
Lower termina (outgoing line) bolt size M10
Материал
Upper terminal Stainless steel 304
Housing Polymer type
Color of housing Dark grey / light grey
Varistor High quality zinc oxide varistor
Size of Varistor 35mm / 38mm /40mm / 42mm
Пакет
Количество/пакет 3 ПК/бумага
Условия обслуживания
Максимальная температура окружающей среды 40 ℃
Уровень загрязнения Heavy
Высота 1000 Метр
Стандартный IEC60099-4:2014

Confirm the selected rating against the system voltage, earthing arrangement, insulation coordination, installation altitude and pollution conditions.

Список контрольных критериев отбора

Prepare the Surge Arrester RFQ

  1. State the system and arrester voltage. Include the nominal system voltage, arrester rated voltage and MCOV.
  2. Confirm discharge duty. Specify nominal discharge current, required residual-voltage limits and the project duty cycle.
  3. Define installation conditions. Include altitude, pollution level, maximum ambient temperature and mounting position.
  4. Select hardware and accessories. Confirm brackets, line clamps, earth leads, disconnectors, bird guards, counters or monitors.
  5. List document requirements. State the applicable standard edition, drawings, test evidence and acceptance documents required by the project.

Configuration and supply boundary

Review the Y5(10)C-11 Configuration

The supplier table lists a polymer housing, Grade 304 stainless steel upper terminal and zinc oxide varistor options sized 35mm / 38mm /40mm / 42mm.

Electrical coordination

Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.

Mounting hardware

State bracket pattern, terminal connection, line clamp and earth-lead requirements in the inquiry.

Failure indication

Confirm whether the supply should include a disconnector, insulating base, counter or monitor.

Commercial boundary

Quantity, packing, delivery schedule, test documents and destination requirements depend on quotation.

Масштаб компании

Fuerte в общих чертах

FUERTE называет 1985 год годом основания, 220+ сотрудников и площадь здания 36 000 м². Эти данные, опубликованные поставщиками, дают представление о масштабах производства и поддержки проектов.

  • Операции на фабрике
  • Тестирование и инспекция
  • Поддержка экспорта

1985

Основанная в

Supplier-published company history

220+

Сотрудники

Published workforce scale

36,000 m²

Застроенная территория

Published manufacturing footprint

OEM

Поддержка ODM

Subject to technical review

О компании FUERTE

Возможность разработки и производства под заказ

Custom Support for Arrester Projects

FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.

  • Electrical configurationReview rated voltage, MCOV, discharge current, residual voltage and service conditions.

  • Hardware selectionConfirm brackets, terminals, disconnectors, bird guards, counters and monitors.

  • Project documentationState drawing, marking, packing and acceptance-document requirements before quotation.

Выставочный зал электротоваров FUERTE

Часто задаваемые вопросы

Y5(10)C-11 Surge Arrester FAQ

What rated voltage and MCOV are published for Y5(10)C-11?

The table lists 11 kV rated voltage and 9.4 kV maximum continuous operating voltage.

What residual-voltage values are shown?

The published steep-current, lightning-impulse and switching-impulse residual voltages are 40 kV, 33 kV and 30 kV crest respectively.

Is the arrester gapped or gapless?

The source identifies the product as a gapless, Design B, distribution-type arrester.

What should the RFQ include?

State the system voltage, MCOV, nominal discharge current, residual-voltage limits, short-circuit requirement, mounting hardware, disconnector, terminal sizes, quantity and destination market.

Обзор конфигурации

Send the Y5(10)C-11 Requirements

Provide system voltage, arrester rated voltage, MCOV, nominal discharge current, residual-voltage limits, mounting and accessory requirements, quantity, destination market and required documents.

Перейдите на форму запроса цены