Electrical coordination
Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.

Medium-voltage isolating switch
GW13-36 Isolating Switch is a medium-voltage isolating switch for outdoor distribution isolation. The supplier table lists 12 / 36 kV rated-voltage options, 630 A rated-current options and 20 kA rated short-circuit withstand current.
The supplier source lists IEC 62271-102:2001. Confirm the required standard edition, test documents and project acceptance scope before ordering.
Published technical data
The table below is transcribed from the target model’s authenticated WordPress source. Confirm the selected voltage, current, withstand level and accessory combination in the RFQ.
| Karakteristik listrik | Spesifikasi | Unit | |
|---|---|---|---|
| Rated voltage of Disconnector | 12 | 36 | kV |
| Nilai arus | 630 | A | |
| Rated frequency | 50 | Hz | |
| Lighting Impulse withstand voltage | 95 | 170 | kV |
| Power frequency withstand voltage in 1 min (Dry) | 42 | 70 | kV |
| Power frequency withstand voltage in 10 s (Wet) | 36 | 60 | kV |
| Rated short circuit withstand current | 20 | kA | |
| Rated short circuit withstand time | 3 | s | |
| Rated peak withstand current | 50 | kA | |
| Creepage | 25 | 20 | mm/kV |
| Blade stopped degree in opening position | 160 | Degree | |
| Suku cadang | |||
| Bracket pemasangan | dengan/tanpa | ||
| Terminal clamp | dengan/tanpa | ||
| Loadbuster Hook | dengan/tanpa | ||
| Self locking Mechanism | with | ||
| Bahan | |||
| Terminal pads | Brass/Copper plated by silver | ||
| Blade | Copper plated by siliver | ||
| Insulator | Porcelain / Polymer | ||
| Channel Base | Steel hot galvanized | ||
| Channel Base | Steel hot galvanized | ||
| Paket | |||
| Jumlah/paket | 1 | PC/karton | |
| Syarat-syarat layanan | |||
| Suhu maksimum lingkungan | 40 | °C | |
| Tingkat polusi | Heavy | ||
| Ketinggian | ≤1000 | Meter | |
| Standard | IEC 62271-102:2001 | ||
Published source values include 50 Hz, 20 mm, 2001. Confirm the exact row and unit in the original technical table when preparing the RFQ.
Confirm system voltage, earthing arrangement, installation altitude, pollution level and required operating duty with the project engineer before final selection.
Checklist seleksi
Configuration and supply boundary
The target source lists selectable hardware and material options. State each option explicitly so the quotation reflects the intended field installation.
Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.
Depending on the model, specify operating mechanism, arcing-distinguishing chamber, operating rod length, loadbuster hook or self-locking mechanism.
The source lists silver-plated copper terminals and blades, porcelain or polymer insulators and hot-galvanized steel bases. Confirm the selected combination.
Quantity, packaging, delivery schedule, private label and project documents remain subject to technical review and quotation.



Skala perusahaan
FUERTE mencatat tahun pendiriannya sebagai tahun 1985, dengan 220+ karyawan dan area bangunan seluas 36.000 m². Angka-angka yang dipublikasikan oleh pemasok tersebut memberikan konteks terkait dengan manufaktur dan dukungan proyek.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
Kemampuan OEM & ODM
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview rated voltage, current, withstand values and service conditions for the target market.
Hardware selectionConfirm poles, operating mechanism, rod length, brackets, terminals and corrosion-resistant materials.
Project documentationState drawings, marking, packing, shipping marks and acceptance-document requirements before quotation.

Pertanyaan yang sering diajukan
The target table lists 12 / 36 kV rated-voltage options and 630 A rated-current options. Confirm the exact configuration in the quotation.
Review impulse withstand, power-frequency withstand, short-circuit withstand current and peak withstand current together with the insulation-coordination study.
The source lists selectable mechanisms, brackets, terminals and, for some models, operating-rod length. Availability depends on technical review.
State model, poles, voltage, current, withstand duty, operating hardware, mounting arrangement, quantity, destination market and required documents.
Ulasan konfigurasi
Provide system voltage, rated current, short-circuit duty, insulation levels, pole arrangement, operating hardware, mounting details, quantity, destination market and required documents.
Tertarik dengan produk ini? Lengkapi formulir di bawah ini dan tim penjualan kami akan menghubungi Anda dalam waktu 24 jam.
Silakan tinggalkan pesan untuk konsultasi. Kami akan menawarkan lebih banyak pilihan layanan untuk Anda.