Saklar Pemisah
Beranda / Produk / Saklar Pemisah / GW13-36 Isolating Switch

Saklar Pemisah

GW13-36 Isolating Switch

  • The disconnect switch / isolating switch with manual operation mechanism is used for sectionalizing or isolating circuits on outdoor distribution overhead systems up to 38KV.
  • Ciri-ciri:
  • Voltage: 12 / 36kV
  • Current: 630A
  • Aplikasi: Jalur Distribusi Atas Atas
  • Standard: IEC 62271-102
Ringkasan

Medium-voltage isolating switch

GW13-36 Isolating Switch for Medium-Voltage Distribution Isolation

GW13-36 Isolating Switch is a medium-voltage isolating switch for outdoor distribution isolation. The supplier table lists 12 / 36 kV rated-voltage options, 630 A rated-current options and 20 kA rated short-circuit withstand current.

Voltan yang diukur
12 / 36 kV
Nilai arus
630 A
Short-circuit withstand
20 kA
Impulse withstand
95 / 170 kV

The supplier source lists IEC 62271-102:2001. Confirm the required standard edition, test documents and project acceptance scope before ordering.

Permintaan tinjauan konfigurasiBrowse isolating switches

Published technical data

GW13-36 Isolating Switch Technical Parameters

The table below is transcribed from the target model’s authenticated WordPress source. Confirm the selected voltage, current, withstand level and accessory combination in the RFQ.

Karakteristik listrik Spesifikasi Unit
Rated voltage of Disconnector 12 36 kV
Nilai arus 630 A
Rated frequency 50 Hz
Lighting Impulse withstand voltage 95 170 kV
Power frequency withstand voltage in 1 min (Dry) 42 70 kV
Power frequency withstand voltage in 10 s  (Wet) 36 60 kV
Rated short circuit withstand current 20 kA
Rated short circuit withstand time 3 s
Rated peak withstand current 50 kA
Creepage 25 20 mm/kV
Blade stopped degree in opening position 160 Degree
Suku cadang
Bracket pemasangan dengan/tanpa
Terminal clamp dengan/tanpa
Loadbuster Hook dengan/tanpa
Self locking Mechanism with
Bahan
Terminal pads Brass/Copper plated by silver
Blade Copper plated by siliver
Insulator Porcelain / Polymer
Channel Base Steel hot galvanized
Channel Base Steel hot galvanized
Paket
Jumlah/paket 1 PC/karton
Syarat-syarat layanan
Suhu maksimum lingkungan 40 °C
Tingkat polusi Heavy
Ketinggian ≤1000 Meter
Standard IEC 62271-102:2001

Published source values include 50 Hz, 20 mm, 2001. Confirm the exact row and unit in the original technical table when preparing the RFQ.

Confirm system voltage, earthing arrangement, installation altitude, pollution level and required operating duty with the project engineer before final selection.

Checklist seleksi

Prepare the Isolating-Switch RFQ

  1. Define the system voltage. State nominal system voltage, rated voltage and insulation-coordination values.
  2. Match continuous and short-time duty. Confirm rated current, short-circuit withstand current, peak withstand current and duration.
  3. Choose the arrangement. Identify single-pole or three-pole construction, operating mechanism and rod length where applicable.
  4. Specify installation hardware. Confirm mounting bracket, terminal clamp, line connection, operating eye and crossarm arrangement.
  5. List documents and quantity. Include standard edition, drawings, test evidence, packing quantity, destination and required delivery schedule for quotation.

Configuration and supply boundary

Review the GW13-36 Configuration

The target source lists selectable hardware and material options. State each option explicitly so the quotation reflects the intended field installation.

Electrical coordination

Confirm rated voltage, current, impulse withstand, power-frequency withstand and leakage distance against the project study.

Operating hardware

Depending on the model, specify operating mechanism, arcing-distinguishing chamber, operating rod length, loadbuster hook or self-locking mechanism.

Materials and corrosion protection

The source lists silver-plated copper terminals and blades, porcelain or polymer insulators and hot-galvanized steel bases. Confirm the selected combination.

Commercial boundary

Quantity, packaging, delivery schedule, private label and project documents remain subject to technical review and quotation.

Skala perusahaan

Fuerte dalam Sekilas

FUERTE mencatat tahun pendiriannya sebagai tahun 1985, dengan 220+ karyawan dan area bangunan seluas 36.000 m². Angka-angka yang dipublikasikan oleh pemasok tersebut memberikan konteks terkait dengan manufaktur dan dukungan proyek.

  • Operasi pabrik
  • Pengujian & Inspeksi
  • Dukungan ekspor

1985

Didirikan pada

Supplier-published company history

220+

Karyawan

Published workforce scale

36,000 m²

Total luas bangunan

Published manufacturing footprint

OEM

& Dukungan ODM

Subject to technical review

Tentang FUERTE

Kemampuan OEM & ODM

Custom Support for Isolating-Switch Projects

FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.

  • Electrical configurationReview rated voltage, current, withstand values and service conditions for the target market.

  • Hardware selectionConfirm poles, operating mechanism, rod length, brackets, terminals and corrosion-resistant materials.

  • Project documentationState drawings, marking, packing, shipping marks and acceptance-document requirements before quotation.

Showroom produk listrik FUERTE

Pertanyaan yang sering diajukan

GW13-36 Isolating Switch FAQ

Which voltage and current values are published?

The target table lists 12 / 36 kV rated-voltage options and 630 A rated-current options. Confirm the exact configuration in the quotation.

What withstand values should be checked?

Review impulse withstand, power-frequency withstand, short-circuit withstand current and peak withstand current together with the insulation-coordination study.

Can the operating hardware be customized?

The source lists selectable mechanisms, brackets, terminals and, for some models, operating-rod length. Availability depends on technical review.

Apa yang harus disertakan dalam permintaan penawaran?

State model, poles, voltage, current, withstand duty, operating hardware, mounting arrangement, quantity, destination market and required documents.

Ulasan konfigurasi

Send the GW13-36 Requirements

Provide system voltage, rated current, short-circuit duty, insulation levels, pole arrangement, operating hardware, mounting details, quantity, destination market and required documents.

Pergi ke formulir penawaran

Permintaan Penawaran Khusus

Tertarik dengan produk ini? Lengkapi formulir di bawah ini dan tim penjualan kami akan menghubungi Anda dalam waktu 24 jam.

Formasi Produk

Siap Membicarakan Kebutuhan Proyek Anda?

Silakan tinggalkan pesan untuk konsultasi. Kami akan menawarkan lebih banyak pilihan layanan untuk Anda.

Formulir Email