Electrical parameters
Confirm rated voltage, current, frequency, short-circuit duty, insulation levels and operating sequence.
Pemutus sirkuit vakum
Column Vacuum Circuit Breaker is presented for medium-voltage switching and protection projects. The authenticated supplier source provides product-specific construction notes and technical rows where published; use the exact model and installation duty for final selection.
The page keeps the supplier’s model identity and source tables where available. Confirm the applicable IEC/GB standard, rated voltage, current, breaking capacity and project acceptance documents before ordering.
Permintaan tinjauan konfigurasiBrowse vacuum circuit breakers
Published technical data
Use the source data below as the starting point for engineering review. Keep voltage class, continuous current, short-circuit duty, operating mechanism and installation environment together when selecting a breaker.
| Voltan yang diukur | kV | 12 |
|---|---|---|
| 1 min rated power-frequency withstand voltage | kV | Phase to phase:42 Phase to ground:42 Fracture:48 |
| Rated lightning impulse withstand voltage (peak value) | kV | Phase to phase:75 Phase to ground:75 Fracture:85 |
| Nilai arus | A | 630 |
| Rated frequency | Hz | 50 |
| Rated short-circuit breaking current | KA | 12.5 16 20 |
| Rated short-circuit making current(peak value) | kA | 31.5 40 50 |
| Rated peak withstand current | kA | 31.5 40 50 |
| 4s rated short-circuit withstand current | KA | 12.5 16 20 |
| Rated operation sequence | open-0.3s-close open-180s-close open | |
| Closing time | ms | 25~60 |
| Opening time | ms | 20~55 |
| Rated short-circult breaking current breaking times | times | 30 |
| Mechanical life | times | 10000 |
| Second-time circuit 1 min power-frequency withstand voltage | V | 2000 |
| Rated power of energy storoge motor | W | 40 |
| Rated voltage of energy storage motor | V | DC220, 110 |
| Rated closing operation voltage | V | DC220, 110 AC220 |
| Rated opening operation voltage | V | DC220, 110 AC220 |
| Motor energy storage time | s | ≤8 |
| Contact travel | mm | 9±1 |
|---|---|---|
| Contact ultra travel | mm | 2±0.5 |
| Central distance of interphase | mm | 340±1.5 |
| Contact bouncing time on closing | ms | ≤ 2 |
| Three-phase non-synchronous opening and closing | ms | ≤2 |
| Average opening speed | m/s | 1.2±0.2 |
| Average closing speed | m/s | 0.6±0.2 |
| Conductive circuit resistance on each phase | μΩ | ≤ 80 |
Values shown are transcribed from the target listing where the authenticated source publishes them. Confirm the exact model row, unit, test condition and revision before using any value in a purchase specification.
Checklist seleksi
Configuration and supply boundary
The supplier listing identifies a vacuum-circuit-breaker model family. State the exact model code and switching arrangement so the quotation does not mix ratings or accessories from another series.
Confirm rated voltage, current, frequency, short-circuit duty, insulation levels and operating sequence.
Specify stored-energy mechanism, motor and coil voltages, auxiliary contacts, interlocks and local/remote control.
Confirm pole arrangement, insulation housing, enclosure, altitude, temperature, pollution and installation interface.
Quantity, packing, delivery schedule, private label and project documents remain subject to technical review and quotation.



Skala perusahaan
FUERTE mencatat tahun pendiriannya sebagai tahun 1985, dengan 220+ karyawan dan area bangunan seluas 36.000 m². Angka-angka yang dipublikasikan oleh pemasok tersebut memberikan konteks terkait dengan manufaktur dan dukungan proyek.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
Kemampuan OEM & ODM
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview voltage class, current rating, insulation levels and service conditions.
Mechanical interfaceConfirm pole structure, operating mechanism, fittings and mounting dimensions.
Project documentationState drawings, wiring, marking, packing, shipping marks and acceptance-document requirements before quotation.

Pertanyaan yang sering diajukan
Start with rated voltage, continuous current, short-circuit breaking capacity, insulation levels, operating sequence and installation environment.
No. Confirm the exact model code and source table. Do not transfer ratings, dimensions or accessories from a similar-looking series.
FUERTE publishes adaptation of mounting hardware and project specifications as an OEM/ODM scope. Availability depends on technical review.
State model, rated voltage, current, breaking duty, mechanism and coil voltages, mounting interface, quantity, destination and required documents.