Spare parts
Mounting bracket: with/without. Arc shortening rod: with/without. Arc distinguish chamber: with/without.
FSC series drop out fuse cutout
FSC series drop out cutout with standard fuse link protects the transformer, capacitors, cables or lines from the short circuit and over load in 11KV~38KV overhead distribution systems.
The FSC-1-1 entry publishes a 10~15 kV voltage range, 100/200/300 A current options, 50/60 Hz frequency and an 8 kA breaking-current value. Confirm the selected fuse link and accessory arrangement before ordering.
The supplier page lists IEC60282-2 as the standard. Confirm the required edition and project acceptance documents before ordering.
Configuration and materials
The original product table separates electrical characteristics, spare parts, material choices, package details and service conditions. Use the table and drawings together when preparing a purchase specification.
Mounting bracket: with/without. Arc shortening rod: with/without. Arc distinguish chamber: with/without.
The source lists the fuse link as without. Confirm whether the project requires a supplied link or a buyer-provided link.
The published material option is Copper with silver plated/Copper with tin plate. Confirm plating and terminal details against the project drawing.
Insulator: Porcelain/Polymer. Fuse tube: Fiber glass. Confirm the required support material before quotation.
The source lists brass copper content as Brass (60~60%), one piece per carton, maximum environment temperature 40 ℃, pollution level II and altitude ≤1000 Meter. Treat these as supplier-stated values and confirm the project service conditions.
Technical parameter
The values below reproduce the target model’s original WordPress table. Electrical coordination, fuse-link selection and final acceptance remain the buyer’s engineering responsibility.
| Parameter | Specification | Unit |
|---|---|---|
| Rated voltage | 10~15 | kV |
| Rated current | 100/200/300 | A |
| Frequency | 50/60 | Hz |
| Power-frequency withstand to earth (1 min) | 42 | kV |
| Power-frequency withstand phase to phase (1 min) | 48 | kV |
| Impulse withstand to earth | 95 | kV |
| Impulse withstand phase to phase | 110 | kV |
| Breaking current | 8 | kA |
| Creepage distance | 220 | mm |
Published values for FSC-1-1 are voltage 10~15 kV, current 100/200/300 A, frequency 50/60 Hz, breaking current 8 kA and creepage distance 220 mm.
Selection checklist
Drawings and supply boundary
The supplier page labels a fuse cutout structure section for this model. Use the first drawing to confirm the main bearing structure and mounting arrangement.
The source lists a lower general bearing of fuse, arc extinguishing housing, American type fusible load with knife and a 300A fusible load. Confirm which accessories are included.


Company scale
FUERTE lists 1985 as its founding year, 220+ employees and a 36,000 m² built-up area. These supplier-published figures provide context for manufacturing and project support.
1985
Decades of manufacturing history
220+
Skilled staff and experienced engineers
36k m²
Supplier-published manufacturing footprint
OEM
Customization subject to project review
OEM & ODM capability
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks. The company also states that it develops customized solutions from technical drawings, market standards and project requirements.
Comprehensive customizationPrivate label, specification adjustment, sample development and mass production.
International experienceFUERTE states it has delivered 100+ customized designs to the USA, Saudi Arabia, Kenya, South Africa, Thailand and other markets.
Cross-category supportAdaptations are listed for fuse cutouts, lightning arresters, isolating switches and related fittings.

Frequently asked questions
The source lists 10~15 kV, 100/200/300 A and 50/60 Hz for this model. Confirm the exact fuse-link and accessory arrangement in the quote request.
Check 42 kV power-frequency withstand to earth, 48 kV phase to phase, 95 kV impulse to earth and 110 kV impulse phase to phase.
The original table shows IEC60282-2. Confirm the required edition and project acceptance documents before ordering.
Confirm model, current, fuse-link arrangement, mounting bracket, spare parts, service conditions, quantity, packaging and destination market.
Configuration review
For an accurate review, provide voltage, current, breaking duty, insulation values, creepage distance, mounting bracket, fuse-link arrangement, order quantity and destination market.
Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.
Please feel free to leave a message for consultation. We will offer you more service options.