{"id":1013,"date":"2026-04-23T08:45:05","date_gmt":"2026-04-23T08:45:05","guid":{"rendered":"https:\/\/cnfuerte.com\/?post_type=product&#038;p=1013"},"modified":"2026-07-08T03:09:21","modified_gmt":"2026-07-08T03:09:21","slug":"zw32-12-630-20-vacuum-circuit-breaker-2","status":"publish","type":"product","link":"https:\/\/cnfuerte.com\/id\/product\/zw32-12-630-20-vacuum-circuit-breaker-2\/","title":{"rendered":"ZW32-12\/630-20 Vacuum Circuit Breaker"},"content":{"rendered":"<table width=\"1497\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr class=\"firstRow\">\n<td class=\"et4\" width=\"54\" height=\"30\"><strong>No<\/strong><\/td>\n<td class=\"et5\" colspan=\"2\" width=\"291\" height=\"30\"><strong>Descriptions<\/strong><\/td>\n<td class=\"et7\" width=\"77\" height=\"30\"><strong>Unit<\/strong><\/td>\n<td class=\"et8\" width=\"300\" height=\"30\"><strong>Standard parameter values<\/strong><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><strong>Note<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"et10\" width=\"54\" height=\"30\"><strong>1.1<\/strong><\/td>\n<td class=\"et11\" colspan=\"4\" width=\"669\" height=\"30\"><strong>Vacuum Circuit Breaker<\/strong><\/td>\n<td class=\"et14\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.1<\/td>\n<td class=\"et16\" width=\"184\" height=\"30\">Model No<\/td>\n<td class=\"et16\" width=\"106\" height=\"30\"><\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">ZW32-12<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et20\" rowspan=\"3\" width=\"54\" height=\"30\">1.1.2<\/td>\n<td class=\"et21\" rowspan=\"3\" width=\"184\" height=\"30\">Switching structure<\/td>\n<td class=\"et16\" width=\"106\" height=\"30\">Transformer form<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">External or internal<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et21\" rowspan=\"2\" width=\"106\" height=\"30\">Insulating Material<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">A: Epoxy resin outsourced silicone rubber<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et26\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et27\" width=\"300\" height=\"30\">B: Outdoor epoxy resin<\/td>\n<td class=\"et28\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.3<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Insulating and extinguishing media<\/td>\n<td class=\"et31\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">Air, Vacuum<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.4<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated Voltage<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">kV<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">12<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.5<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated Current<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">A<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">630<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.6<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated cable charging and breaking current<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">A<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">20<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.7<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated short-circuit breaking current<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">kA<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">12.5, 16, 20<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.8<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Temperature rise test current<\/td>\n<td class=\"et26\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et27\" width=\"300\" height=\"30\">1.1Ir<\/td>\n<td class=\"et28\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et20\" rowspan=\"2\" width=\"54\" height=\"30\">1.1.9<\/td>\n<td class=\"et21\" rowspan=\"2\" width=\"184\" height=\"30\">Rated frequency 1 min withstand voltage<\/td>\n<td class=\"et29\" width=\"106\" height=\"30\">To earth\/Between<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">kV<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">42<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et29\" width=\"106\" height=\"30\">Across the base<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">kV<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">48<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et20\" rowspan=\"2\" width=\"54\" height=\"30\">1.1.10<\/td>\n<td class=\"et21\" rowspan=\"2\" width=\"184\" height=\"30\">Rated lightning impulse withstand voltage(1.2\/50\u03bcs)Peak value<\/td>\n<td class=\"et29\" width=\"106\" height=\"30\">To earth\/Between<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">kV<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">75<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et29\" width=\"106\" height=\"30\">Across the base<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">kV<\/td>\n<td class=\"et27\" width=\"300\" height=\"30\">85<\/td>\n<td class=\"et28\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.11<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated short-time withstand current and duration<\/td>\n<td class=\"et33\" width=\"77\" height=\"30\">kA\/s<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">20\/3<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.12<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated peak withstand current<\/td>\n<td class=\"et33\" width=\"77\" height=\"30\">kA<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">50<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.13<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated short-circuit breaking current<\/td>\n<td class=\"et33\" width=\"77\" height=\"30\">kA<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">20<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.14<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated short-circuit closing current<\/td>\n<td class=\"et34\" width=\"77\" height=\"30\">kA<\/td>\n<td class=\"et27\" width=\"300\" height=\"30\">50<\/td>\n<td class=\"et28\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.15<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Main circuit resistance<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">\u03bc\u03a9<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">80<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.16<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Mechanical stability<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">times<\/td>\n<td class=\"et35\" width=\"300\" height=\"30\"><span class=\"font4\">\u2265<\/span><span class=\"font6\">10000 No load<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.17<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Minimum creepage distance for external insulation<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">mm<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">372<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.18<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated short-circuit breaking current breaking times<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">times<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\"><span class=\"font4\">\u2265<\/span><span class=\"font6\">30times<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.19<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Closing and opening not synchronized<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">ms<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\"><span class=\"font4\">\u2264<\/span><span class=\"font6\">2<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.20<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Contact closing bounce time<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">ms<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\"><span class=\"font4\">\u2264<\/span><span class=\"font6\">2<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.1.21<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\"><span class=\"font6\">Partial discharge<\/span><span class=\"font4\">\uff08<\/span><span class=\"font6\">1.1Ur<\/span><span class=\"font4\">\uff09<\/span><\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">pC<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\"><span class=\"font4\">\u2264<\/span><span class=\"font6\">20<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et10\" width=\"54\" height=\"30\"><strong>1.2<\/strong><\/td>\n<td class=\"et11\" colspan=\"4\" width=\"669\" height=\"30\"><strong>Operating Mechanism<\/strong><\/td>\n<td class=\"et36\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.2.1<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Type or model of actuator<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">Spring or permanent magnet mechanism<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.2.2<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Operating Method<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">Motorized with manual operation<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.2.3<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Motor Voltage<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">V<\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">Conventional DC220<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.2.4<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Auxiliary contact capacity<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\"><span class=\"font6\">DC24V<\/span><span class=\"font4\">\u3001<\/span><span class=\"font6\">10A<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.2.5<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">DC resistance of telecommunication circuit<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\"><span class=\"font6\">After 100times operations<\/span><span class=\"font4\">\uff1c<\/span><span class=\"font6\">1\u03a9<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.3<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Transformer combination mode<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">Includes current transformers, electronic zero sequence voltage transformers, and electromagnetic voltage transformers or other models.<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et10\" width=\"54\" height=\"30\"><strong>1.4<\/strong><\/td>\n<td class=\"et11\" colspan=\"4\" width=\"669\" height=\"30\"><strong>Current Transformer<\/strong><\/td>\n<td class=\"et36\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.4.1<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated current ratio<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">(1) Phase current: 600A\/5A<br \/>\n(2) Zero sequence current: 100A\/1A<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et37\" width=\"54\" height=\"30\">1.4.2<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Accuracy Level<\/td>\n<td class=\"et16\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">(1) Phase current: protection class 5P10<br \/>\n(2) Zero sequence current: use 100A\/1A<br \/>\nProtection Class 10P30.<\/td>\n<td class=\"et32\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.4.3<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Implementation method<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">Electromagnetic<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.4.4<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Temperature range<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et38\" width=\"300\" height=\"30\"><span class=\"font6\">-40<\/span><span class=\"font4\">\u2103\uff5e<\/span><span class=\"font6\">70<\/span><span class=\"font4\">\u2103<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et10\" width=\"54\" height=\"30\"><strong>1.5<\/strong><\/td>\n<td class=\"et11\" colspan=\"4\" width=\"669\" height=\"30\"><strong>Electromagnetic voltage transformers(external)<\/strong><\/td>\n<td class=\"et14\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.5.1<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Rated Voltage Ratio<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">Zero sequence voltage: (10kV\/)\/( 6.5V\/3)<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.5.2<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Accuracy Level<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">Zero sequence voltage: 3P level<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.5.3<\/td>\n<td class=\"et29\" colspan=\"2\" width=\"291\" height=\"30\">Temperature range<\/td>\n<td class=\"et26\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et38\" width=\"300\" height=\"30\"><span class=\"font6\">-40<\/span><span class=\"font4\">\u2103\uff5e<\/span><span class=\"font6\">70<\/span><span class=\"font4\">\u2103<\/span><\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et20\" width=\"54\" height=\"30\">1.5.4<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Partial discharge<\/td>\n<td class=\"et26\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">\u226420 (1.1Um)<\/td>\n<td class=\"et19\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.5.5<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Load Impedance<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et42\" width=\"300\" height=\"30\"><span class=\"font4\">\u2265<\/span><span class=\"font6\">2M\u03a9<\/span><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et43\" width=\"54\" height=\"30\"><strong>1.6<\/strong><\/td>\n<td class=\"et11\" colspan=\"4\" width=\"669\" height=\"30\"><strong>Electromagnetic voltage transformers (external)<\/strong><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.6.1<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Quantities<\/td>\n<td class=\"et17\" width=\"77\" height=\"30\">PC<\/td>\n<td class=\"et44\" width=\"300\" height=\"30\">1 or 2 optional<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.6.2<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Rated Voltage Ratio<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et44\" width=\"300\" height=\"30\">Line voltage measurement: 10kV\/0.1kV<br \/>\nSupply voltage: 10kV\/0.22kV<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.6.3<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Accuracy level<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et44\" width=\"300\" height=\"30\">Measuring voltage winding: 0.5 level<br \/>\nSupply voltage winding: 3 levels<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.6.4<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Capacity (VA)<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et44\" width=\"300\" height=\"30\"><span class=\"font6\">Measuring voltage winding:\u00a0<\/span><span class=\"font4\">\u2265<\/span><span class=\"font6\">10VA<br \/>\nSupply voltage winding: long-term capacity\u00a0<\/span><span class=\"font4\">\u2265<\/span><span class=\"font6\">\u00a050VA, short-time capacity\u00a0<\/span><span class=\"font4\">\u2265<\/span><span class=\"font6\">\u00a0300VA\/30s<\/span><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et43\" width=\"54\" height=\"30\"><strong>1.7<\/strong><\/td>\n<td class=\"et11\" colspan=\"4\" width=\"669\" height=\"30\"><strong>Mechanical property<\/strong><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.1<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Contact opening distance<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">mm<\/td>\n<td class=\"et44\" width=\"300\" height=\"30\">9\u00b11<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.2<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">contact overtravel<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">mm<\/td>\n<td class=\"et44\" width=\"300\" height=\"30\">2.5\u00b10.5<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.3<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Average closing speed<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">m\/s<\/td>\n<td class=\"et44\" width=\"300\" height=\"30\">0.4-0.8<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.4<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Average gate opening speed<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">m\/s<\/td>\n<td class=\"et44\" width=\"300\" height=\"30\">1.0-1.4<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.5<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Closing time<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">ms<\/td>\n<td class=\"et42\" width=\"300\" height=\"30\"><span class=\"font4\">\u2264<\/span><span class=\"font6\">60<\/span><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.6<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Split time<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">ms<\/td>\n<td class=\"et42\" width=\"300\" height=\"30\"><span class=\"font4\">\u2264<\/span><span class=\"font6\">\u00a045<\/span><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.7<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Closing Bounce Time<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">ms<\/td>\n<td class=\"et42\" width=\"300\" height=\"30\"><span class=\"font4\">\u2264<\/span><span class=\"font5\">2<\/span><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.8<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Three-phase switching non-synchronous<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">ms<\/td>\n<td class=\"et42\" width=\"300\" height=\"30\"><span class=\"font4\">\u2264<\/span><span class=\"font6\">2<\/span><\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et15\" width=\"54\" height=\"30\">1.7.9<\/td>\n<td class=\"et39\" colspan=\"2\" width=\"291\" height=\"30\">Interphase center distance<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\">mm<\/td>\n<td class=\"et44\" width=\"300\" height=\"30\">340\u00b11.5<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et45\" width=\"54\" height=\"30\">1.8<\/td>\n<td class=\"et46\" colspan=\"2\" width=\"291\" height=\"30\">Enclosure protection class<\/td>\n<td class=\"et48\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et49\" width=\"300\" height=\"30\">Not less than IP65<\/td>\n<td class=\"et9\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et50\" width=\"54\" height=\"30\">1.10<\/td>\n<td class=\"et16\" colspan=\"2\" width=\"291\" height=\"30\">Case Material<\/td>\n<td class=\"et41\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et18\" width=\"300\" height=\"30\">304 or hot rolled steel<\/td>\n<td class=\"et32\" width=\"299\" height=\"30\">Support for surface treatment<\/td>\n<\/tr>\n<tr>\n<td class=\"et51\" width=\"54\" height=\"30\"><strong>1.11\u00a0<\/strong><\/td>\n<td class=\"et11\" colspan=\"4\" width=\"669\" height=\"30\"><strong>Secondary equipment<\/strong><\/td>\n<td class=\"et52\" width=\"299\" height=\"30\"><\/td>\n<\/tr>\n<tr>\n<td class=\"et53\" width=\"54\" height=\"30\">1.11.1<\/td>\n<td class=\"et54\" colspan=\"2\" width=\"291\" height=\"30\">Intelligent Control Terminal<\/td>\n<td class=\"et55\" width=\"77\" height=\"30\"><\/td>\n<td class=\"et56\" width=\"300\" height=\"30\">Support remote on-site, three protection, three remote, reclosing, SOE, can also be equipped with statute communication to connect the background of real-time monitoring, adjusting, issuing fixed value configuration, other requirements when ordering.<\/td>\n<td class=\"et32\" width=\"299\" height=\"30\">One or two times are connected by aviation plug-in, without external wiring.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>No Descriptions Unit Standard parameter values Note 1.1 Vacuum Circuit Breaker 1.1.1 Model No ZW32-12 1.1.2 Switching structure Transformer form External or internal Insulating Material A: Epoxy resin outsourced silicone rubber B: Outdoor epoxy resin 1.1.3 Insulating and extinguishing media Air, Vacuum 1.1.4 Rated Voltage kV 12 1.1.5 Rated Current A 630 1.1.6 Rated cable [&hellip;]<\/p>\n","protected":false},"featured_media":1015,"template":"","meta":{"_gspb_post_css":""},"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":["post-1013","product","type-product","status-publish","has-post-thumbnail","product_cat-vacuum-circuit-breaker","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnfuerte.com\/id\/wp-json\/wp\/v2\/product\/1013","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnfuerte.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnfuerte.com\/id\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnfuerte.com\/id\/wp-json\/wp\/v2\/media\/1015"}],"wp:attachment":[{"href":"https:\/\/cnfuerte.com\/id\/wp-json\/wp\/v2\/media?parent=1013"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnfuerte.com\/id\/wp-json\/wp\/v2\/product_brand?post=1013"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnfuerte.com\/id\/wp-json\/wp\/v2\/product_cat?post=1013"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnfuerte.com\/id\/wp-json\/wp\/v2\/product_tag?post=1013"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}