Electrical coordination
Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.


Metal oxide surge arrester
The supplier table identifies YH5(10)W-36 / YH5(10)W-36J / YH5(10)W-36L as a 36 kV, 50 Hz, gapless Design B distribution-type surge arrester with 5 / 10 kA nominal discharge-current options and 29 kV maximum continuous operating voltage.
The source lists IEC60099-4:2014. Confirm the required standard edition, arrester class and project acceptance documents before ordering.
Published technical data
Review the published electrical characteristics together with the selectable accessories, material options, package information and service conditions.
| Karakteristik listrik | Spesifikasi | Unit | |
|---|---|---|---|
| Rated voltage of Surge arrreser | 36 | kV | |
| Nominal discharge current | 5 | 10 | kA |
| Rated frequency | 50 | Hz | |
| Maximum continuous operating voltage | 29 | kV | |
| Steep current impulse residual voltage | 123 | kV(Crest) | |
| Lightning Impulse residual voltage | 108 | kV(Crest) | |
| Switching Impulse residual voltage | 92.4 | kV(Crest) | |
| Long duration current impulse
withstand voltage |
150 | 250 | A |
| High current impulses | 65 | 100 | kA (Crest) |
| Rated Short-circuit current | 20 / 12 / 6 / 0.6 ± 0.2 | kA | |
| Class of Surge arrester | Class 1 or Class 2 | ||
| Permohonan | Distribution type | ||
| With or without gap | Gapless | ||
| Designation of arrester | Design B | ||
| Suku cadang | |||
| NEMA A or B mounting bracket | dengan/tanpa | ||
| Pemutus daya | dengan/tanpa | ||
| Earth lead | dengan/tanpa | ||
| Bird guard cap | dengan/tanpa | ||
| Line clamp | dengan/tanpa | ||
| Upper terminal (incoming line) bolt size | M12 | ||
| Lower termina (outgoing line) bolt size | M10 | ||
| Bahan | |||
| Upper terminal | Stainless steel 304 | ||
| Housing | Polymer type | ||
| Color of housing | Dark grey / light grey | ||
| Varistor | High quality zinc oxide varistor | ||
| Size of Varistor | 35mm / 38mm /40mm / 42mm | ||
| Paket | |||
| Jumlah/paket | 3 | PC/karton | |
| Syarat-syarat layanan | |||
| Suhu maksimum lingkungan | 40 | ℃ | |
| Tingkat polusi | Heavy | ||
| Ketinggian | 1000 | Meter | |
| Standard | IEC60099-4:2014 | ||
Confirm the selected rating against the system voltage, earthing arrangement, insulation coordination, installation altitude and pollution conditions.
Checklist seleksi
Configuration and supply boundary
The supplier table lists a polymer housing, Grade 304 stainless steel upper terminal and zinc oxide varistor options sized 35mm / 38mm /40mm / 42mm.
Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.
State bracket pattern, terminal connection, line clamp and earth-lead requirements in the inquiry.
Confirm whether the supply should include a disconnector, insulating base, counter or monitor.
Quantity, packing, delivery schedule, test documents and destination requirements depend on quotation.



Skala perusahaan
FUERTE mencatat tahun pendiriannya sebagai tahun 1985, dengan 220+ karyawan dan area bangunan seluas 36.000 m². Angka-angka yang dipublikasikan oleh pemasok tersebut memberikan konteks terkait dengan manufaktur dan dukungan proyek.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
Kemampuan OEM & ODM
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview rated voltage, MCOV, discharge current, residual voltage and service conditions.
Hardware selectionConfirm brackets, terminals, disconnectors, bird guards, counters and monitors.
Project documentationState drawing, marking, packing and acceptance-document requirements before quotation.

Pertanyaan yang sering diajukan
The table lists 36 kV rated voltage and 29 kV maximum continuous operating voltage.
The published steep-current, lightning-impulse and switching-impulse residual voltages are 123 kV, 108 kV and 92.4 kV crest respectively.
The source identifies the product as a gapless, Design B, distribution-type arrester.
State the system voltage, MCOV, nominal discharge current, residual-voltage limits, short-circuit requirement, mounting hardware, disconnector, terminal sizes, quantity and destination market.
Ulasan konfigurasi
Provide system voltage, arrester rated voltage, MCOV, nominal discharge current, residual-voltage limits, mounting and accessory requirements, quantity, destination market and required documents.
Tertarik dengan produk ini? Lengkapi formulir di bawah ini dan tim penjualan kami akan menghubungi Anda dalam waktu 24 jam.
Silakan tinggalkan pesan untuk konsultasi. Kami akan menawarkan lebih banyak pilihan layanan untuk Anda.