Y5(10)W-24 Surge Arrester

  • Penangkal lonjakan listrik dipasang di atas transformator distribusi tegangan tinggi, di mana ia menyalurkan energi dari peristiwa tegangan berlebih (terutama akibat petir) ke koneksi tanah dan melindungi peralatan dari kerusakan dalam sistem.
  • Ciri-ciri:
  • Voltage: 24kV
  • Current: 5kA / 10kA
  • Aplikasi: Jalur Distribusi Atas Atas
  • Standar: IEC60099-4
Ringkasan

Metal oxide surge arrester

Y5(10)W-24 Surge Arrester for Distribution Overvoltage Protection

The supplier table identifies Y5(10)W-24 as a 24 kV, 50 Hz, gapless Design B distribution-type surge arrester with 5 / 10 kA nominal discharge-current options and 19.5 kV maximum continuous operating voltage.

Voltan yang diukur
24 kV
Nominal discharge current
5 / 10 kA
MCOV
19.5 kV
Published standard
IEC60099-4:2014

The source lists IEC60099-4:2014. Confirm the required standard edition, arrester class and project acceptance documents before ordering.

Permintaan tinjauan konfigurasiBrowse lightning arresters

Published technical data

Y5(10)W-24 Technical Parameters

Review the published electrical characteristics together with the selectable accessories, material options, package information and service conditions.

Karakteristik listrik Spesifikasi Unit
Rated voltage of Surge arrreser 24 kV
Nominal discharge current 5 10 kA
Rated frequency 50 Hz
Maximum continuous operating voltage 19.5 kV
Steep current impulse residual voltage 82 kV(Crest)
Lightning Impulse residual voltage 72 kV(Crest)
Switching Impulse residual voltage 62 kV(Crest)
Long duration current impulse

withstand voltage

150 250 A
High current impulses 65 100 kA (Crest)
Rated Short-circuit current 20 / 12 / 6 / 0.6 ± 0.2 kA
Class of Surge arrester Class 1 or Class 2
Permohonan Distribution type
With or without gap Gapless
Designation of arrester Design B
Suku cadang
NEMA A or B mounting bracket dengan/tanpa
Pemutus daya dengan/tanpa
Earth lead dengan/tanpa
Bird guard cap dengan/tanpa
Line clamp dengan/tanpa
Upper terminal (incoming line) bolt size M12
Lower termina (outgoing line) bolt size M10
Bahan
Upper terminal Stainless steel 304
Housing Polymer type
Color of housing Dark grey / light grey
Varistor High quality zinc oxide varistor
Size of Varistor 35mm / 38mm /40mm / 42mm
Paket
Jumlah/paket 3 PC/karton
Syarat-syarat layanan
Suhu maksimum lingkungan 40 ℃
Tingkat polusi Heavy
Ketinggian 1000 Meter
Standard IEC60099-4:2014

Confirm the selected rating against the system voltage, earthing arrangement, insulation coordination, installation altitude and pollution conditions.

Checklist seleksi

Prepare the Surge Arrester RFQ

  1. State the system and arrester voltage. Include the nominal system voltage, arrester rated voltage and MCOV.
  2. Confirm discharge duty. Specify nominal discharge current, required residual-voltage limits and the project duty cycle.
  3. Define installation conditions. Include altitude, pollution level, maximum ambient temperature and mounting position.
  4. Select hardware and accessories. Confirm brackets, line clamps, earth leads, disconnectors, bird guards, counters or monitors.
  5. List document requirements. State the applicable standard edition, drawings, test evidence and acceptance documents required by the project.

Configuration and supply boundary

Review the Y5(10)W-24 Configuration

The supplier table lists a polymer housing, Grade 304 stainless steel upper terminal and zinc oxide varistor options sized 35mm / 38mm /40mm / 42mm.

Electrical coordination

Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.

Mounting hardware

State bracket pattern, terminal connection, line clamp and earth-lead requirements in the inquiry.

Failure indication

Confirm whether the supply should include a disconnector, insulating base, counter or monitor.

Commercial boundary

Quantity, packing, delivery schedule, test documents and destination requirements depend on quotation.

Skala perusahaan

Fuerte dalam Sekilas

FUERTE mencatat tahun pendiriannya sebagai tahun 1985, dengan 220+ karyawan dan area bangunan seluas 36.000 m². Angka-angka yang dipublikasikan oleh pemasok tersebut memberikan konteks terkait dengan manufaktur dan dukungan proyek.

  • Operasi pabrik
  • Pengujian & Inspeksi
  • Dukungan ekspor

1985

Didirikan pada

Supplier-published company history

220+

Karyawan

Published workforce scale

36,000 m²

Total luas bangunan

Published manufacturing footprint

OEM

& Dukungan ODM

Subject to technical review

Tentang FUERTE

Kemampuan OEM & ODM

Custom Support for Arrester Projects

FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.

  • Electrical configurationReview rated voltage, MCOV, discharge current, residual voltage and service conditions.

  • Hardware selectionConfirm brackets, terminals, disconnectors, bird guards, counters and monitors.

  • Project documentationState drawing, marking, packing and acceptance-document requirements before quotation.

Showroom produk listrik FUERTE

Pertanyaan yang sering diajukan

Y5(10)W-24 Surge Arrester FAQ

What rated voltage and MCOV are published for Y5(10)W-24?

The table lists 24 kV rated voltage and 19.5 kV maximum continuous operating voltage.

What residual-voltage values are shown?

The published steep-current, lightning-impulse and switching-impulse residual voltages are 82 kV, 72 kV and 62 kV crest respectively.

Is the arrester gapped or gapless?

The source identifies the product as a gapless, Design B, distribution-type arrester.

What should the RFQ include?

State the system voltage, MCOV, nominal discharge current, residual-voltage limits, short-circuit requirement, mounting hardware, disconnector, terminal sizes, quantity and destination market.

Ulasan konfigurasi

Send the Y5(10)W-24 Requirements

Provide system voltage, arrester rated voltage, MCOV, nominal discharge current, residual-voltage limits, mounting and accessory requirements, quantity, destination market and required documents.

Pergi ke formulir penawaran

Permintaan Penawaran Khusus

Tertarik dengan produk ini? Lengkapi formulir di bawah ini dan tim penjualan kami akan menghubungi Anda dalam waktu 24 jam.

Formasi Produk

Siap Membicarakan Kebutuhan Proyek Anda?

Silakan tinggalkan pesan untuk konsultasi. Kami akan menawarkan lebih banyak pilihan layanan untuk Anda.

Formulir Email