{"id":1105,"date":"2026-04-24T03:17:15","date_gmt":"2026-04-24T03:17:15","guid":{"rendered":"https:\/\/cnfuerte.com\/?post_type=product&#038;p=1105"},"modified":"2026-07-08T08:40:11","modified_gmt":"2026-07-08T08:40:11","slug":"fxb-15-polymer-insulator","status":"publish","type":"product","link":"https:\/\/cnfuerte.com\/fr\/product\/fxb-15-polymer-insulator\/","title":{"rendered":"FXB-15 Polymer Insulator"},"content":{"rendered":"<p><strong>Pin Type Insulator<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1109\" src=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-1.webp\" alt=\"\" width=\"1000\" height=\"642\" srcset=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-1.webp 1000w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-1-600x385.webp 600w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-1-300x193.webp 300w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-1-768x493.webp 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<table width=\"741\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"top\" width=\"60\">Model<\/td>\n<td valign=\"top\" width=\"46\">Rated Voltage<\/td>\n<td valign=\"top\" width=\"105\">Rated Mecha\u00a0nical Bending Load<\/td>\n<td valign=\"top\" width=\"53\">Stucture Height<\/td>\n<td valign=\"top\" width=\"72\">Creepage distance<\/td>\n<td valign=\"top\" width=\"133\">Lightning Impulse withstand Voltage<\/td>\n<td valign=\"top\" width=\"160\">Power-frequency withstand Voltage\u00a0\uff08wet\uff09<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"60\"><\/td>\n<td valign=\"top\" width=\"46\">kV<\/td>\n<td valign=\"top\" width=\"105\">kN<\/td>\n<td valign=\"top\" width=\"53\">mm<\/td>\n<td valign=\"top\" width=\"72\">mm<\/td>\n<td valign=\"top\" width=\"133\">kV<\/td>\n<td valign=\"top\" width=\"160\">kV<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"60\">FPQ3-10\/4T20<\/td>\n<td valign=\"top\" width=\"46\">10~15<\/td>\n<td valign=\"top\" width=\"105\">4<\/td>\n<td valign=\"top\" width=\"53\">326<\/td>\n<td valign=\"top\" width=\"72\">460<\/td>\n<td valign=\"top\" width=\"133\">95<\/td>\n<td valign=\"top\" width=\"160\">42<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"60\">FPQ3-24\/5T22<\/td>\n<td valign=\"top\" width=\"46\">24~27<\/td>\n<td valign=\"top\" width=\"105\">5<\/td>\n<td valign=\"top\" width=\"53\">403<\/td>\n<td valign=\"top\" width=\"72\">700<\/td>\n<td valign=\"top\" width=\"133\">150<\/td>\n<td valign=\"top\" width=\"160\">65<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"60\">FPQ2-24\/13T20<\/td>\n<td valign=\"top\" width=\"46\">24~27<\/td>\n<td valign=\"top\" width=\"105\">13<\/td>\n<td valign=\"top\" width=\"53\">298<\/td>\n<td valign=\"top\" width=\"72\">760<\/td>\n<td valign=\"top\" width=\"133\">170<\/td>\n<td valign=\"top\" width=\"160\">80<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"60\">FPQ2-36\/8T22<\/td>\n<td valign=\"top\" width=\"46\">33~36<\/td>\n<td valign=\"top\" width=\"105\">8<\/td>\n<td valign=\"top\" width=\"53\">403<\/td>\n<td valign=\"top\" width=\"72\">1080<\/td>\n<td valign=\"top\" width=\"133\">210<\/td>\n<td valign=\"top\" width=\"160\">110<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Suspension Type Insulator<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1108\" src=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-2.webp\" alt=\"\" width=\"1000\" height=\"663\" srcset=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-2.webp 1000w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-2-600x398.webp 600w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-2-300x199.webp 300w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-2-768x509.webp 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<table width=\"741\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"top\" width=\"66\">Model<\/td>\n<td valign=\"top\" width=\"59\">Rated Voltage<\/td>\n<td valign=\"top\" width=\"112\">Rated Mechanical Bending Load<\/td>\n<td valign=\"top\" width=\"52\">Stucture Height<\/td>\n<td valign=\"top\" width=\"76\">Creepage distance<\/td>\n<td valign=\"top\" width=\"131\">Lightning Impulse withstand Voltage<\/td>\n<td valign=\"top\" width=\"133\">Power-frequency withstand Voltage\u00a0\uff08wet\uff09<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\"><\/td>\n<td valign=\"top\" width=\"59\">kV<\/td>\n<td valign=\"top\" width=\"112\">kN<\/td>\n<td valign=\"top\" width=\"52\">mm<\/td>\n<td valign=\"top\" width=\"76\">mm<\/td>\n<td valign=\"top\" width=\"131\">kV<\/td>\n<td valign=\"top\" width=\"133\">kV<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\">FZSW1-15<\/td>\n<td valign=\"top\" width=\"59\">15<\/td>\n<td valign=\"top\" width=\"112\">10<\/td>\n<td valign=\"top\" width=\"52\">178<\/td>\n<td valign=\"top\" width=\"76\">400<\/td>\n<td valign=\"top\" width=\"131\">110<\/td>\n<td valign=\"top\" width=\"133\">42<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\">FZSW1-27<\/td>\n<td valign=\"top\" width=\"59\">27<\/td>\n<td valign=\"top\" width=\"112\">8<\/td>\n<td valign=\"top\" width=\"52\">209<\/td>\n<td valign=\"top\" width=\"76\">530<\/td>\n<td valign=\"top\" width=\"131\">150<\/td>\n<td valign=\"top\" width=\"133\">65<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\">FZSW1-36<\/td>\n<td valign=\"top\" width=\"59\">36<\/td>\n<td valign=\"top\" width=\"112\">6<\/td>\n<td valign=\"top\" width=\"52\">273<\/td>\n<td valign=\"top\" width=\"76\">750<\/td>\n<td valign=\"top\" width=\"131\">170<\/td>\n<td valign=\"top\" width=\"133\">75<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\">FZSW2-36\/4<\/td>\n<td valign=\"top\" width=\"59\">36<\/td>\n<td valign=\"top\" width=\"112\">4<\/td>\n<td valign=\"top\" width=\"52\">397<\/td>\n<td valign=\"top\" width=\"76\">1080<\/td>\n<td valign=\"top\" width=\"131\">200<\/td>\n<td valign=\"top\" width=\"133\">95<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Post type insulator<\/strong><\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1107\" src=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-3.webp\" alt=\"\" width=\"1000\" height=\"522\" srcset=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-3.webp 1000w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-3-600x313.webp 600w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-3-300x157.webp 300w, https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/FXB-15-Polymer-Insulator-3-768x401.webp 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/strong><\/p>\n<table width=\"741\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"top\" width=\"66\" height=\"10\">Model<\/td>\n<td valign=\"top\" width=\"67\" height=\"10\">Rated Voltage<\/td>\n<td valign=\"top\" width=\"93\" height=\"10\">Rated Mechanical Bending Load<\/td>\n<td valign=\"top\" width=\"60\" height=\"10\">Stucture Height<\/td>\n<td valign=\"top\" width=\"61\" height=\"10\">Creepage distance<\/td>\n<td valign=\"top\" width=\"134\" height=\"10\">Lightning Impulse withstand Voltage<\/td>\n<td valign=\"top\" width=\"148\" height=\"10\">Power-frequency withstand Voltage\u00a0\uff08wet\uff09<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\" height=\"10\"><\/td>\n<td valign=\"top\" width=\"67\" height=\"10\">kV<\/td>\n<td valign=\"top\" width=\"93\" height=\"10\">kN<\/td>\n<td valign=\"top\" width=\"60\" height=\"10\">mm<\/td>\n<td valign=\"top\" width=\"61\" height=\"10\">mm<\/td>\n<td valign=\"top\" width=\"134\" height=\"10\">kV<\/td>\n<td valign=\"top\" width=\"148\" height=\"10\">kV<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\" height=\"30\">FZSW1-15<\/td>\n<td valign=\"top\" width=\"67\" height=\"30\">15<\/td>\n<td valign=\"top\" width=\"93\" height=\"30\">10<\/td>\n<td valign=\"top\" width=\"60\" height=\"30\">178<\/td>\n<td valign=\"top\" width=\"61\" height=\"30\">400<\/td>\n<td valign=\"top\" width=\"134\" height=\"30\">110<\/td>\n<td valign=\"top\" width=\"148\" height=\"30\">42<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\" height=\"30\">FZSW1-27<\/td>\n<td valign=\"top\" width=\"67\" height=\"30\">27<\/td>\n<td valign=\"top\" width=\"93\" height=\"30\">8<\/td>\n<td valign=\"top\" width=\"60\" height=\"30\">209<\/td>\n<td valign=\"top\" width=\"61\" height=\"30\">530<\/td>\n<td valign=\"top\" width=\"134\" height=\"30\">150<\/td>\n<td valign=\"top\" width=\"148\" height=\"30\">65<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\" height=\"30\">FZSW1-36<\/td>\n<td valign=\"top\" width=\"67\" height=\"30\">36<\/td>\n<td valign=\"top\" width=\"93\" height=\"30\">6<\/td>\n<td valign=\"top\" width=\"60\" height=\"30\">273<\/td>\n<td valign=\"top\" width=\"61\" height=\"30\">750<\/td>\n<td valign=\"top\" width=\"134\" height=\"30\">170<\/td>\n<td valign=\"top\" width=\"148\" height=\"30\">75<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"66\" height=\"30\">FZSW2-36\/4<\/td>\n<td valign=\"top\" width=\"67\" height=\"30\">36<\/td>\n<td valign=\"top\" width=\"93\" height=\"30\">4<\/td>\n<td valign=\"top\" width=\"60\" height=\"30\">397<\/td>\n<td valign=\"top\" width=\"61\" height=\"30\">1080<\/td>\n<td valign=\"top\" width=\"134\" height=\"30\">200<\/td>\n<td valign=\"top\" width=\"148\" height=\"30\">95<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<ul>\n<li>Polymer insulator has pin, post and suspension type rated from 10kV to 36kV, which housed by silicone rubber has good property such as water-proof, anti-ageing,<\/li>\n<li>tracking-proof, anti-corrosion, anti-impulse, shaking-proof, high strength,\u00a0light weight,easy installation etc.It guarantees electrical insulation and mechanical\u00a0mounting for overhead distribution and transmission line.<\/li>\n<li>Technical Standard: IEC61109, IEC61952, ANSI C29 latest standard.<\/li>\n<\/ul>","protected":false},"featured_media":1106,"template":"","meta":{"_gspb_post_css":""},"product_brand":[],"product_cat":[33],"product_tag":[],"class_list":["post-1105","product","type-product","status-publish","has-post-thumbnail","product_cat-polymer-insulator","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnfuerte.com\/fr\/wp-json\/wp\/v2\/product\/1105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnfuerte.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnfuerte.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnfuerte.com\/fr\/wp-json\/wp\/v2\/media\/1106"}],"wp:attachment":[{"href":"https:\/\/cnfuerte.com\/fr\/wp-json\/wp\/v2\/media?parent=1105"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnfuerte.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1105"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnfuerte.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1105"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnfuerte.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}