Coordination de l'isolement
Confirm rated voltage, impulse withstand, power-frequency withstand, insulating distance and creepage distance.
Polymer insulator
FXB-24 Polymer Insulator is a silicone-rubber polymer insulator family for overhead distribution and substation insulation. The authenticated supplier tables publish 10–36 rated-voltage rows, mechanical bending-load options and insulation dimensions for pin, suspension and post-type arrangements.
The source publishes model-specific electrical and mechanical values but does not state a single standard for every row. Confirm the applicable IEC/ANSI edition and project acceptance documents before ordering.
Demander une révision de la configurationBrowse polymer insulators
Published technical data
The tables below are transcribed from the target model’s authenticated WordPress source. Keep the type, voltage class, mechanical load and insulation distances together when selecting a model.
| Model | Rated Voltage | Rated Mecha nical Bending Load | Stucture Height | Ligne de fuite | Lightning Impulse withstand Voltage | Power-frequency withstand Voltage (wet) |
|---|---|---|---|---|---|---|
| kV | kN | mm | mm | kV | kV | |
| FPQ3-10/4T20 | 10~15 | 4 | 326 | 460 | 95 | 42 |
| FPQ3-24/5T22 | 24~27 | 5 | 403 | 700 | 150 | 65 |
| FPQ2-24/13T20 | 24~27 | 13 | 298 | 760 | 170 | 80 |
| FPQ2-36/8T22 | 33~36 | 8 | 403 | 1080 | 210 | 110 |
| Model | Rated Voltage | Rated Mechanical Bending Load | Stucture Height | Ligne de fuite | Lightning Impulse withstand Voltage | Power-frequency withstand Voltage (wet) |
|---|---|---|---|---|---|---|
| kV | kN | mm | mm | kV | kV | |
| FZSW1-15 | 15 | 10 | 178 | 400 | 110 | 42 |
| FZSW1-27 | 27 | 8 | 209 | 530 | 150 | 65 |
| FZSW1-36 | 36 | 6 | 273 | 750 | 170 | 75 |
| FZSW2-36/4 | 36 | 4 | 397 | 1080 | 200 | 95 |
| Model | Rated Voltage | Rated Mechanical Bending Load | Stucture Height | Ligne de fuite | Lightning Impulse withstand Voltage | Power-frequency withstand Voltage (wet) |
|---|---|---|---|---|---|---|
| kV | kN | mm | mm | kV | kV | |
| FZSW1-15 | 15 | 10 | 178 | 400 | 110 | 42 |
| FZSW1-27 | 27 | 8 | 209 | 530 | 150 | 65 |
| FZSW1-36 | 36 | 6 | 273 | 750 | 170 | 75 |
| FZSW2-36/4 | 36 | 4 | 397 | 1080 | 200 | 95 |
The authenticated source contains the technical tables below; confirm the exact model row and unit before ordering.
Liste de contrôle de sélection
Configuration and supply boundary
The target source presents model families and dimensional variants. State the exact model code and installation arrangement so the quotation does not mix pin, suspension and post-type data.
Confirm rated voltage, impulse withstand, power-frequency withstand, insulating distance and creepage distance.
Specify bending load, structure height, hardware and the pole or crossarm interface required on site.
Confirm silicone-rubber housing, end fittings, pollution level, altitude and any corrosion or tracking requirements.
Quantity, packing, delivery schedule, private label and project documents remain subject to technical review and quotation.
Taille de l'entreprise
FUERTE indique 1985 comme année de fondation, plus de 220 employés et une superficie bâtie de 36 000 m². Ces chiffres publiés par le fournisseur fournissent un contexte pour la fabrication et le support de projets.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
Capacité OEM & ODM
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview voltage class, insulation levels, creepage distance and service conditions.
Mechanical interfaceConfirm construction type, fittings, mounting dimensions and mechanical load.
Project documentationState drawings, marking, packing, shipping marks and acceptance-document requirements before quotation.

Foire aux questions
Start with construction type, rated voltage, mechanical load, impulse withstand and creepage or insulating distance.
No. The source publishes separate tables. Confirm the exact arrangement and model code before using any row in a purchase specification.
FUERTE publishes adaptation of mounting hardware and project specifications as an OEM/ODM scope. Availability depends on technical review.
State model, construction type, voltage, mechanical load, insulation levels, mounting interface, quantity, destination and required documents.
Examen de la configuration
Provide construction type, rated voltage, mechanical load, insulation levels, dimensions, mounting details, quantity, destination market and required documents.
Ce produit vous intéresse ? Remplissez le formulaire ci-dessous et notre équipe commerciale vous recontactera dans les 24 heures.
N'hésitez pas à laisser un message pour consultation. Nous vous proposerons davantage d'options de service.