Electrical parameters
Confirm rated voltage, current, frequency, short-circuit duty, insulation levels and operating sequence.
Disjoncteur à vide
Vacuum Circuit Breaker is presented for medium-voltage switching and protection projects. The authenticated supplier source provides product-specific construction notes and technical rows where published; use the exact model and installation duty for final selection.
The page keeps the supplier’s model identity and source tables where available. Confirm the applicable IEC/GB standard, rated voltage, current, breaking capacity and project acceptance documents before ordering.
Demander une révision de la configurationBrowse vacuum circuit breakers
Published technical data
Use the source data below as the starting point for engineering review. Keep voltage class, continuous current, short-circuit duty, operating mechanism and installation environment together when selecting a breaker.
| Tension nominale | kV | 12 |
|---|---|---|
| 1 min rated power-frequency withstand voltage (effective value) | kV | Phase to phase:42 Phase to ground:42 Fracture:48 |
| Rated lightning impulse withstand voltage (peak value) | kV | Phase to phase:75 Phase to ground:75 Fracture:85 |
| Courant assigné | A | 630 |
| Fréquence assignée | Hz | 50 |
| Rated short-circuit breaking current(effective value) | kA | 12.5 16 20 25 |
| Rated short-circuit making current(peak value) | kA | 31.5 40 50 63 |
| Rated peak withstand current | kA | 31.5 40 50 63 |
| 4s rated short-circuit withstand current (effective value) | kA | 12.5 16 20 25 |
| Rated operation sequence | open-0.3s-close open-180s-close open | |
| Rated short-circuit breaking current breaking times | times | 30 |
| Mechanical life | times | 10000 |
| Second-time circuit 1 min power-frequency withstand voltage | V | 2000 |
| Weight | Kg | 145 |
| Contact distance | mm | 9±1 |
|---|---|---|
| Contact ultra travel | mm | 3±1 |
| Contact bouncing time on closing | ms | ≤2 |
| Three-phase non-synchronous opening | ms | ≤2 |
| Average opening speed | m/s | 0.65±0.2 |
| Average closing speed | m/s | 1.2±0.2 |
| Closing time | ms | 30~100 |
| Opening time | ms | 25~60 |
| Central distance of interphase | mm | 275 |
| Main circuit resistance | μΩ | ≤120 |
| SF6 gas pressure | Mpa | 0 |
Values shown are transcribed from the target listing where the authenticated source publishes them. Confirm the exact model row, unit, test condition and revision before using any value in a purchase specification.
Liste de contrôle de sélection
Configuration and supply boundary
The supplier listing identifies a vacuum-circuit-breaker model family. State the exact model code and switching arrangement so the quotation does not mix ratings or accessories from another series.
Confirm rated voltage, current, frequency, short-circuit duty, insulation levels and operating sequence.
Specify stored-energy mechanism, motor and coil voltages, auxiliary contacts, interlocks and local/remote control.
Confirm pole arrangement, insulation housing, enclosure, altitude, temperature, pollution and installation interface.
Quantity, packing, delivery schedule, private label and project documents remain subject to technical review and quotation.
Taille de l'entreprise
FUERTE indique 1985 comme année de fondation, plus de 220 employés et une superficie bâtie de 36 000 m². Ces chiffres publiés par le fournisseur fournissent un contexte pour la fabrication et le support de projets.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
Capacité OEM & ODM
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview voltage class, current rating, insulation levels and service conditions.
Mechanical interfaceConfirm pole structure, operating mechanism, fittings and mounting dimensions.
Project documentationState drawings, wiring, marking, packing, shipping marks and acceptance-document requirements before quotation.

Foire aux questions
Start with rated voltage, continuous current, short-circuit breaking capacity, insulation levels, operating sequence and installation environment.
No. Confirm the exact model code and source table. Do not transfer ratings, dimensions or accessories from a similar-looking series.
FUERTE publishes adaptation of mounting hardware and project specifications as an OEM/ODM scope. Availability depends on technical review.
State model, rated voltage, current, breaking duty, mechanism and coil voltages, mounting interface, quantity, destination and required documents.
Examen de la configuration
Provide rated voltage, current, breaking duty, insulation levels, mechanism, dimensions, mounting details, quantity, destination market and required documents.