Pararrayos
Inicio / Productos / Pararrayos / Y5(10)W-11 Surge Arrester

Pararrayos

Y5(10)W-11 Surge Arrester

  • The surge arrester is assembled above overhead distribution transformers, where they shunt the energy from overvoltage events (especially lightning effects) to a ground connection and protect the equipment against damage in system.
  • Características:
  • Voltage: 11kV
  • Current: 5kA / 10kA
  • Application: Overhead Distribution Line
  • Standard: IEC60099-4
Resumen

Metal oxide surge arrester

Y5(10)W-11 Surge Arrester for Distribution Overvoltage Protection

The supplier table identifies Y5(10)W-11 as a 11 kV, 50 Hz, gapless Design B distribution-type surge arrester with 5 / 10 kA nominal discharge-current options and 9.4 kV maximum continuous operating voltage.

Tensión nominal
11 kV
Nominal discharge current
5 / 10 kA
MCOV
9.4 kV
Published standard
IEC60099-4:2014

The source lists IEC60099-4:2014. Confirm the required standard edition, arrester class and project acceptance documents before ordering.

Solicite una revisión de la configuraciónBrowse lightning arresters

Published technical data

Y5(10)W-11 Technical Parameters

Review the published electrical characteristics together with the selectable accessories, material options, package information and service conditions.

Características eléctricas Especificaciones Unidad
Rated voltage of Surge arrreser 11 kV
Nominal discharge current 5 10 kA
Rated frequency 50 Hz
Maximum continuous operating voltage 9.4 kV
Steep current impulse residual voltage 40 kV(Crest)
Lightning Impulse residual voltage 33 kV(Crest)
Switching Impulse residual voltage 30 kV(Crest)
Long duration current impulse

withstand voltage

150 250 A
High current impulses 65 100 kA (Crest)
Rated Short-circuit current 20 / 12 / 6 / 0.6 ± 0.2 kA
Class of Surge arrester Class 1 or Class 2
Aplicación Distribution type
With or without gap Gapless
Designation of arrester Design B
Repuestos
NEMA A or B mounting bracket con/sin
Disjuntor con/sin
Earth lead con/sin
Bird guard cap con/sin
Line clamp con/sin
Upper terminal (incoming line) bolt size M12
Lower termina (outgoing line) bolt size M10
Material
Upper terminal Stainless steel 304
Housing Polymer type
Color of housing Dark grey / light grey
Varistor High quality zinc oxide varistor
Size of Varistor 35mm / 38mm /40mm / 42mm
Paquete
Cantidad/paquete 3 PC/caja de cartón
Condiciones de servicio
Temperatura máxima del entorno 40 ℃
Nivel de contaminación Heavy
Altitud 1000 Métrica
Estándar IEC60099-4:2014

Confirm the selected rating against the system voltage, earthing arrangement, insulation coordination, installation altitude and pollution conditions.

Lista de verificación de selección

Prepare the Surge Arrester RFQ

  1. State the system and arrester voltage. Include the nominal system voltage, arrester rated voltage and MCOV.
  2. Confirm discharge duty. Specify nominal discharge current, required residual-voltage limits and the project duty cycle.
  3. Define installation conditions. Include altitude, pollution level, maximum ambient temperature and mounting position.
  4. Select hardware and accessories. Confirm brackets, line clamps, earth leads, disconnectors, bird guards, counters or monitors.
  5. List document requirements. State the applicable standard edition, drawings, test evidence and acceptance documents required by the project.

Configuration and supply boundary

Review the Y5(10)W-11 Configuration

The supplier table lists a polymer housing, Grade 304 stainless steel upper terminal and zinc oxide varistor options sized 35mm / 38mm /40mm / 42mm.

Electrical coordination

Confirm rated voltage, MCOV, nominal discharge current and residual-voltage limits against the project study.

Mounting hardware

State bracket pattern, terminal connection, line clamp and earth-lead requirements in the inquiry.

Failure indication

Confirm whether the supply should include a disconnector, insulating base, counter or monitor.

Commercial boundary

Quantity, packing, delivery schedule, test documents and destination requirements depend on quotation.

Escala de la empresa

Fuerte a primera vista

FUERTE menciona el año 1985 como su año de fundación, 220 empleados y una superficie construida de 36.000 m². Estas cifras publicadas por los proveedores proporcionan contexto para la fabricación y el apoyo a los proyectos.

  • Operaciones en fábrica
  • Test y inspección
  • Suporte a la exportación

1985

Fundada en

Supplier-published company history

220+

Empleados

Published workforce scale

36,000 m²

Área construida

Published manufacturing footprint

OEM

Suporte a ODM

Subject to technical review

Sobre FUERTE

Capacidad de OEM y ODM

Custom Support for Arrester Projects

FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.

  • Electrical configurationReview rated voltage, MCOV, discharge current, residual voltage and service conditions.

  • Hardware selectionConfirm brackets, terminals, disconnectors, bird guards, counters and monitors.

  • Project documentationState drawing, marking, packing and acceptance-document requirements before quotation.

Showroom de productos eléctricos FUERTE

Preguntas frecuentes

Y5(10)W-11 Surge Arrester FAQ

What rated voltage and MCOV are published for Y5(10)W-11?

The table lists 11 kV rated voltage and 9.4 kV maximum continuous operating voltage.

What residual-voltage values are shown?

The published steep-current, lightning-impulse and switching-impulse residual voltages are 40 kV, 33 kV and 30 kV crest respectively.

Is the arrester gapped or gapless?

The source identifies the product as a gapless, Design B, distribution-type arrester.

What should the RFQ include?

State the system voltage, MCOV, nominal discharge current, residual-voltage limits, short-circuit requirement, mounting hardware, disconnector, terminal sizes, quantity and destination market.

Revisión de la configuración

Send the Y5(10)W-11 Requirements

Provide system voltage, arrester rated voltage, MCOV, nominal discharge current, residual-voltage limits, mounting and accessory requirements, quantity, destination market and required documents.

Acceda al formulario de cotización

Solicite un presupuesto personalizado

¿Está interesado en este producto? Complete el formulario que aparece a continuación y nuestro equipo de ventas se pondrá en contacto con usted dentro de las 24 horas.

Forma del producto

¿Listo para hablar sobre los requisitos de su proyecto?

No dude en dejar un mensaje para consulta. Le ofreceremos más opciones de servicio.

Formulario de correo electrónico