{"id":1940,"date":"2026-07-30T02:00:00","date_gmt":"2026-07-30T02:00:00","guid":{"rendered":"https:\/\/cnfuerte.com\/?p=1940"},"modified":"2026-07-30T02:00:00","modified_gmt":"2026-07-30T02:00:00","slug":"surge-protection-solar-power-plants-dc-mv","status":"publish","type":"post","link":"https:\/\/cnfuerte.com\/ar\/blog\/surge-protection-solar-power-plants-dc-mv\/","title":{"rendered":"Surge Protection for Solar Power Plants: Separate DC and MV Decisions"},"content":{"rendered":"<p style=\"margin:0 0 16px;line-height:1.7\">Ask for a lightning arrester for solar power plant protection and you are really asking two questions at once. One concerns the DC side \u2014 modules, combiner boxes, and inverter interfaces \u2014 where surge protection means low-voltage SPD equipment specified under its own published standard. The other concerns the medium-voltage side \u2014 collection circuits and the step-up transformer area \u2014 where the subject is a metal-oxide arrester application with system-level inputs.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Treating those as one purchase produces quotes that cannot be compared and evidence that cannot be audited. This guide separates the two decisions and shows what each needs. One boundary is stated up front: the FUERTE portfolio discussed on this site covers medium-voltage arresters, not DC-side PV SPDs.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"YH510W-12 and YH510W-12J surge arrester product-family context for solar plant MV-side review\" src=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/YH510W-12-YH510W-12J-Surge-Arrester.1.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 style=\"margin:42px 0 14px\">Contents<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#part-1-one-plant-two-surge-protection-decisions\">Part 1. One plant, two surge-protection decisions<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-2-the-dc-side-is-its-own-specification\">Part 2. The DC side is its own specification<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-3-the-mv-side-is-arrester-territory\">Part 3. The MV side is arrester territory<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-4-inputs-the-mv-arrester-review-needs\">Part 4. Inputs the MV arrester review needs<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-5-keep-the-two-scopes-separate-in-the-rfq\">Part 5. Keep the two scopes separate in the RFQ<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-6-evidence-to-request-on-each-side\">Part 6. Evidence to request on each side<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-7-fuerte-product-context-on-the-mv-side-only\">Part 7. FUERTE product context on the MV side only<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px\" id=\"part-1-one-plant-two-surge-protection-decisions\">Part 1. One plant, two surge-protection decisions<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A utility-scale photovoltaic plant crosses two electrical worlds. Energy is generated and collected at low-voltage DC, converted by inverters, then stepped up and moved through a medium-voltage collection system toward the grid connection.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Surge protection follows that split. Devices near modules, combiner boxes, and inverters belong to the low-voltage SPD category, while the collection circuits and the step-up transformer area raise a classic metal-oxide arrester application question. Naming makes this confusing \u2014 both get called lightning protection \u2014 and the <a href=\"https:\/\/cnfuerte.com\/ar\/blog\/the-difference-between-surge-arrester-and-lightning-arrester\/\">difference between surge arrester and lightning arrester<\/a> is worth one link rather than a re-explanation here.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">What matters for procurement is that the two categories carry different specifications, different standards context, different suppliers, and different evidence. Every section below keeps them apart.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-2-the-dc-side-is-its-own-specification\">Part 2. The DC side is its own specification<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">DC-side surge protection is specified as SPD equipment for photovoltaic installations. A dedicated published standard exists for exactly this scope \u2014 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/30774\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61643-32<\/a> covers SPDs connected to the DC side of photovoltaic installations, including selection and application principles \u2014 and the DC design team applies it together with the inverter manufacturer&#8217;s interface requirements and the owner&#8217;s engineering rules.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This article does not specify DC SPDs, and neither does this site&#8217;s portfolio. <strong>DC-side PV SPDs are a different product category and are not part of the FUERTE medium-voltage arrester portfolio discussed here.<\/strong> Issue the DC scope to SPD suppliers as its own package, reviewed by the team that owns the array and inverter design.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Two practical consequences follow. First, no MV arrester quotation should be read as covering module, combiner, or inverter protection. Second, a DC SPD datasheet answers nothing about the collection system, so neither document substitutes for the other.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-3-the-mv-side-is-arrester-territory\">Part 3. The MV side is arrester territory<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Once energy leaves the inverters and enters the MV collection system, the surge-protection question changes shape. Collection feeders, switching equipment, and the step-up transformer area are reviewed the way other medium-voltage assets are reviewed, and metal-oxide arresters are the product category under discussion \u2014 the <a href=\"https:\/\/cnfuerte.com\/ar\/lightning-arrester\/\">lightning arrester portfolio<\/a> shows what that family looks like at product level.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Where arresters sit within the plant is a project-engineering outcome, not a catalog default. Typical review points include the collection-system equipment positions and the step-up transformer terminals, with locations, quantities, and mounting arrangements settled by the project drawings and study assumptions.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Published application guidance exists for this side too: <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33842\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60099-5<\/a> collects selection and application recommendations for surge arresters. For broader system context, the live article on <a href=\"https:\/\/cnfuerte.com\/ar\/blog\/lightning-surge-arrester-for-power-grids-reliable-protection-for-industrial-electrical-systems\/\">lightning surge arresters for power grids<\/a> covers grid and industrial framing; this page stays on the solar-plant scope split.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-4-inputs-the-mv-arrester-review-needs\">Part 4. Inputs the MV arrester review needs<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">The MV-side review consumes system facts, and a solar plant has some facts worth writing down early because they differ from a generic feeder. The table keeps the inputs at the level a buyer can assemble without inventing engineering values.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">MV-side input<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">What the record should contain<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Common solar-plant note<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Single-line diagram<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Collection circuits, switching points, step-up transformer position<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Multiple identical feeders still need one controlled diagram<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">System voltage record<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nominal and maximum operating conditions used by the project<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Collection-system voltage is a project fact, not a guess from module count<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Grounding description<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Grounding method and neutral treatment of the MV system<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Plant grounding layouts vary; state what applies, do not assume<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Transformer data reference<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Step-up transformer insulation and terminal information<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Needed before any terminal-protection discussion<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Location and layout<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Intended arrester positions, mounting, and lead routing context<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Outdoor plant structures shape the installed geometry<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Governing criteria<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Owner rules or study assumptions that control acceptance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Named documents with revisions, not verbal expectations<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">For the step-up transformer specifically, the coordination inputs are already organized in the live article on <a href=\"https:\/\/cnfuerte.com\/ar\/blog\/transformer-surge-arresters-coordination-questions\/\">transformer surge arrester coordination questions<\/a>. Use it as the checklist for that terminal-level review; this page does not restate it.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">No numeric ratings appear in this list on purpose. Voltage classes, protective levels, and energy figures belong to the project engineer and the exact quoted SKU documentation, never to a marketing page.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-5-keep-the-two-scopes-separate-in-the-rfq\">Part 5. Keep the two scopes separate in the RFQ<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">RFQ scope is where the split either survives or dies. A single line item called &#8220;lightning protection for plant&#8221; invites suppliers to interpret the boundary themselves, and every interpretation will differ.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">RFQ control<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">DC scope package<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">MV scope package<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Product category<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Low-voltage PV SPD equipment<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Medium-voltage metal-oxide arresters<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Standards context<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">DC PV SPD standard context named by the owner<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Arrester application recommendations named by the owner<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Recipients<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SPD suppliers and the inverter-side design team<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Arrester suppliers and the MV design team<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Inputs attached<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Array, combiner, and inverter interface documents<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Single-line, voltage, grounding, transformer, layout records<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Evidence requested<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SPD documentation per its own standard context<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SKU datasheet, drawings, and requested test evidence<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Award logic<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Evaluated within the DC package<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Evaluated within the MV package<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Separate packages also protect the schedule. DC SPD decisions move with the inverter and array design, while MV arrester decisions move with the collection-system and transformer engineering; chaining them into one award forces the slower track to block the faster one.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-6-evidence-to-request-on-each-side\">Part 6. Evidence to request on each side<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Evidence requests only work when they name the exact configuration. For the MV package, ask each bidder to identify the exact quoted SKU and revision, then require the datasheet, drawing, and any owner-requested test or type evidence to reference that same configuration. Exceptions belong in a written list, not in silence.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">The DC package follows the same discipline under its own category: the SPD supplier documents its products against the DC standard context the owner named. Keep the two evidence sets in separate files so an auditor can trace each decision to its own inputs.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">MV-side scope can extend beyond the arrester units themselves. Where the owner specifies condition-monitoring accessories \u2014 monitoring devices or discharge counters mounted with the arresters \u2014 their documentation is requested inside the same MV package, against the same exact-SKU discipline.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Real-time monitoring device product context from the FUERTE medium-voltage arrester accessory range\" src=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/Monitor.2.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Safety procedures stay with the owner regardless of scope. Equipment procurement does not replace controlled isolation and energized-work rules, and the <a href=\"https:\/\/www.osha.gov\/electrical\" rel=\"nofollow noopener\" target=\"_blank\">OSHA electrical safety topic<\/a> is a public reference for how such processes are framed; the owner&#8217;s and local jurisdiction&#8217;s rules govern the site.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-7-fuerte-product-context-on-the-mv-side-only\">Part 7. FUERTE product context on the MV side only<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">When the MV inputs from Part 4 are assembled, a buyer can route an SKU-level documentation request to a specific product family. The <a href=\"https:\/\/cnfuerte.com\/ar\/product\/yh510w-12-yh510w-12j-surge-arrester\/\">YH510W-12\/YH510W-12J Surge Arrester<\/a> page is one such destination in the FUERTE metal-oxide family; its parameters live on that page and apply to the exact SKU it describes.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"YH510W-12 and YH510W-12J surge arrester product view for MV-side documentation requests\" src=\"https:\/\/cnfuerte.com\/wp-content\/uploads\/2026\/04\/YH510W-12-YH510W-12J-Surge-Arrester.2.webp\" \/><\/figure>\n<h3 style=\"margin:28px 0 12px\">Product recommendation fit boundary<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No product page decides plant fit. Whether YH510W-12, YH510W-12J, or any other model suits a specific collection system or step-up transformer is settled by the project&#8217;s MV inputs, the study or owner criteria, and the quoted-SKU documents \u2014 and the DC-side SPD scope remains outside this portfolio entirely. Buyers with the single-line diagram, voltage and grounding records, transformer data, and layout context ready can <a href=\"https:\/\/cnfuerte.com\/ar\/contact-us\/\">send the MV-side evidence pack<\/a> for an SKU-level response.<\/p>\n<h2 style=\"margin:42px 0 14px\">FAQ<\/h2>\n<h3 style=\"margin:28px 0 12px\">Does one device protect a whole solar power plant from lightning surges?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. The DC side and the MV side raise separate surge-protection questions with different product categories, standards context, and evidence. A plant-level answer requires both scopes to be reviewed by their own design teams.<\/p>\n<h3 style=\"margin:28px 0 12px\">What is the difference between a DC SPD and an MV surge arrester?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">A DC SPD is low-voltage equipment applied around modules, combiner boxes, and inverter interfaces under PV-specific SPD standards context. An MV surge arrester is a metal-oxide device reviewed against collection-system and transformer-level inputs such as system voltage, grounding, and insulation records.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which standard covers SPDs on the DC side of PV installations?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">A dedicated published standard exists for that scope: IEC 61643-32, covering SPDs connected to the DC side of photovoltaic installations with selection and application principles. The DC design team applies it; this article only points to it.<\/p>\n<h3 style=\"margin:28px 0 12px\">Does FUERTE supply DC-side SPDs for PV arrays?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. DC-side PV SPDs are a different product category and are not part of the FUERTE medium-voltage arrester portfolio discussed on this site. FUERTE context in a solar project belongs to the MV collection and step-up side.<\/p>\n<h3 style=\"margin:28px 0 12px\">Where do MV arresters sit in a solar plant?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Review points are set by project engineering, typically around collection-system equipment and the step-up transformer terminals. Locations, quantities, and mounting arrangements come from the plant drawings and study assumptions, not from a catalog default.<\/p>\n<h3 style=\"margin:28px 0 12px\">What inputs does the MV-side arrester review need?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">A controlled single-line diagram, system voltage records, the grounding and neutral-treatment description, the step-up transformer data reference, intended locations with layout context, and the governing owner or study criteria \u2014 with all numeric ratings left to the engineer and the exact quoted SKU documents.<\/p>\n<h3 style=\"margin:28px 0 12px\">How should an RFQ separate DC and MV surge protection scopes?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Issue two packages with their own product categories, standards context, recipients, inputs, and evidence lists, and evaluate each on its own track. A single mixed line item produces non-comparable quotes and an unauditable boundary.<\/p>\n<h3 style=\"margin:28px 0 12px\">Can a product page prove a solar-plant application fit?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. A product page identifies a family and carries the SKU-level data to verify, but fit is established by the project&#8217;s MV inputs and the quoted-SKU documentation reviewed together by the project engineer.<\/p>\n<h2 style=\"margin:42px 0 14px\">References<\/h2>\n<ol style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">DC-side standard scope: <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/30774\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61643-32, SPDs connected to the d.c. side of photovoltaic installations<\/a><\/li>\n<li style=\"margin:0 0 8px\">MV-side application recommendations scope: <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33842\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60099-5, Surge arresters \u2014 Selection and application recommendations<\/a><\/li>\n<li style=\"margin:0 0 8px\">Electrical safety-process context: <a href=\"https:\/\/www.osha.gov\/electrical\" rel=\"nofollow noopener\" target=\"_blank\">OSHA electrical safety topic<\/a><\/li>\n<li style=\"margin:0 0 8px\">Public terminology context: <a href=\"https:\/\/en.wikipedia.org\/wiki\/Surge_arrester\" rel=\"nofollow noopener\" target=\"_blank\">Wikipedia: Surge arrester<\/a><\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Ask for a lightning arrester for solar power plant protection and you are really asking two questions at once. One concerns the DC side \u2014 modules, combiner boxes, and inverter interfaces \u2014 where surge protection means low-voltage SPD equipment specified under its own published standard. The other concerns the medium-voltage side \u2014 collection circuits and [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":1437,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1940","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"_links":{"self":[{"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/posts\/1940","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/comments?post=1940"}],"version-history":[{"count":1,"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/posts\/1940\/revisions"}],"predecessor-version":[{"id":1991,"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/posts\/1940\/revisions\/1991"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/media\/1437"}],"wp:attachment":[{"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/media?parent=1940"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/categories?post=1940"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnfuerte.com\/ar\/wp-json\/wp\/v2\/tags?post=1940"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}