Insulation coordination
Confirm rated voltage, impulse withstand, power-frequency withstand, insulating distance and creepage distance.
Polymer insulator
FXBUW-10 Polymer Insulator is a silicone-rubber polymer insulator family for overhead distribution and substation insulation. The authenticated supplier tables publish 10–36 rated-voltage rows, mechanical bending-load options and insulation dimensions for pin, suspension and post-type arrangements.
The source publishes model-specific electrical and mechanical values but does not state a single standard for every row. Confirm the applicable IEC/ANSI edition and project acceptance documents before ordering.
Published technical data
The tables below are transcribed from the target model’s authenticated WordPress source. Keep the type, voltage class, mechanical load and insulation distances together when selecting a model.
| Model | Rated Voltage | Rated Mecha nical Bending Load | Stucture Height | Creepage distance | Lightning Impulse withstand Voltage | Power-frequency withstand Voltage (wet) |
|---|---|---|---|---|---|---|
| kV | kN | mm | mm | kV | kV | |
| FPQ3-10/4T20 | 10~15 | 4 | 326 | 460 | 95 | 42 |
| FPQ3-24/5T22 | 24~27 | 5 | 403 | 700 | 150 | 65 |
| FPQ2-24/13T20 | 24~27 | 13 | 298 | 760 | 170 | 80 |
| FPQ2-36/8T22 | 33~36 | 8 | 403 | 1080 | 210 | 110 |
| Model | Rated Voltage | Rated Mechanical Bending Load | Stucture Height | Creepage distance | Lightning Impulse withstand Voltage | Power-frequency withstand Voltage (wet) |
|---|---|---|---|---|---|---|
| kV | kN | mm | mm | kV | kV | |
| FZSW1-15 | 15 | 10 | 178 | 400 | 110 | 42 |
| FZSW1-27 | 27 | 8 | 209 | 530 | 150 | 65 |
| FZSW1-36 | 36 | 6 | 273 | 750 | 170 | 75 |
| FZSW2-36/4 | 36 | 4 | 397 | 1080 | 200 | 95 |
| Model | Rated Voltage | Rated Mechanical Bending Load | Stucture Height | Creepage distance | Lightning Impulse withstand Voltage | Power-frequency withstand Voltage (wet) |
|---|---|---|---|---|---|---|
| kV | kN | mm | mm | kV | kV | |
| FZSW1-15 | 15 | 10 | 178 | 400 | 110 | 42 |
| FZSW1-27 | 27 | 8 | 209 | 530 | 150 | 65 |
| FZSW1-36 | 36 | 6 | 273 | 750 | 170 | 75 |
| FZSW2-36/4 | 36 | 4 | 397 | 1080 | 200 | 95 |
The authenticated source contains the technical tables below; confirm the exact model row and unit before ordering.
Selection checklist
Configuration and supply boundary
The target source presents model families and dimensional variants. State the exact model code and installation arrangement so the quotation does not mix pin, suspension and post-type data.
Confirm rated voltage, impulse withstand, power-frequency withstand, insulating distance and creepage distance.
Specify bending load, structure height, hardware and the pole or crossarm interface required on site.
Confirm silicone-rubber housing, end fittings, pollution level, altitude and any corrosion or tracking requirements.
Quantity, packing, delivery schedule, private label and project documents remain subject to technical review and quotation.
Company scale
FUERTE lists 1985 as its founding year, 220+ employees and a 36,000 m² built-up area. These supplier-published figures provide context for manufacturing and project support.
1985
Supplier-published company history
220+
Published workforce scale
36,000 m²
Published manufacturing footprint
OEM
Subject to technical review
OEM & ODM capability
FUERTE’s published OEM and ODM scope includes voltage/current adaptation, mounting hardware, nameplates, packaging and shipping marks.
Electrical configurationReview voltage class, insulation levels, creepage distance and service conditions.
Mechanical interfaceConfirm construction type, fittings, mounting dimensions and mechanical load.
Project documentationState drawings, marking, packing, shipping marks and acceptance-document requirements before quotation.

Frequently asked questions
Start with construction type, rated voltage, mechanical load, impulse withstand and creepage or insulating distance.
No. The source publishes separate tables. Confirm the exact arrangement and model code before using any row in a purchase specification.
FUERTE publishes adaptation of mounting hardware and project specifications as an OEM/ODM scope. Availability depends on technical review.
State model, construction type, voltage, mechanical load, insulation levels, mounting interface, quantity, destination and required documents.
Configuration review
Provide construction type, rated voltage, mechanical load, insulation levels, dimensions, mounting details, quantity, destination market and required documents.
Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.
Please feel free to leave a message for consultation. We will offer you more service options.